muuniiTargetRSSI
TRANGOP5830S-MU-MIB ·
.1.3.6.1.4.1.5454.1.22.2.6.5
Object
scalar
mandatory
r/w
Integer32
This object is only applicable to M5830S/P5830S radio. UNII RF target RSSI (in dBm). It specifies the target RSSI from remote unit to the master unit. Based on this parameter, the master can power level the remote unit so that it receives same level of signal strength from the remote unit, regardless far or near. Note that when you set the Target RSSI from the remote unit, you need to consider remote unit's RF Rx Threshold value. The Target RSSI from the remote unit must be 5dB higher than the RF Rx Threshold.
Context
- MIB
- TRANGOP5830S-MU-MIB
- OID
.1.3.6.1.4.1.5454.1.22.2.6.5- Type
- scalar
- Access
- readwrite
- Status
- mandatory
- Parent
- muunii
- Siblings
- 4
Syntax
Integer32
Values & Constraints
Object Constraints
range: -85--45
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| muuniiTxPowerMax mandatory This object is only applicable to M5830S/P5830S radio.
The maximum UNII Tx power value can be set (in dBm). | scalar | Integer32 | .1.3.6.1.4.1.5454.1.22.2.6.1 |
| muuniiTxPowerMin mandatory This object is only applicable to M5830S/P5830S radio.
The minimum UNII Tx power value can be set (in dBm). | scalar | Integer32 | .1.3.6.1.4.1.5454.1.22.2.6.2 |
| muuniiTxPower mandatory This object is only applicable to M5830S/P5830S radio.
UNII RF tx power (in dBm). It specifies the power output
of the radio, excluding the antenna gain. Check parameters
apuniiTx… | scalar | Integer32 | .1.3.6.1.4.1.5454.1.22.2.6.3 |
| muuniiRxThreshold mandatory This object is only applicable to M5830S/P5830S radio.
UNII RF rx threshold (in dBm). It specifies the receiver sensitivity of the master. | scalar | Integer32 | .1.3.6.1.4.1.5454.1.22.2.6.4 |