tmnxTwampSrvPfxMaxConnsExceeded

TIMETRA-TWAMP-MIB · .1.3.6.1.4.1.6527.3.1.3.76.0.3

Object

notification
[CAUSE] The tmnxTwampSrvPfxMaxConnsExceeded notification is generated
when a TWAMP control connection could not be established by the TWAMP
server because the maximum number of concurrent TWAMP control
connections configured against the TWAMP client's prefix
(tmnxTwampSrvPrefixMaxConnections) has been reached.
          
[EFFECT] The TWAMP client cannot request test runs on the rejected
connection.
          
[RECOVERY] Configure the prefix's maximum number of concurrent TWAMP
control connections to a larger value, or disconnect a TWAMP control
connection which uses the prefix.