svcMacFdbTblFullAlarm

TIMETRA-SERV-MIB · .1.3.6.1.4.1.6527.3.1.3.4.2.0.36

Object

notification obsolete
[CAUSE] The svcMacFdbTblFullAlarm notification is raised when system
limit of FDB records is reached.
          
Further traps are not generated as long as the value of
svcMacFdbRecords object remains under 5 percent of the limit.
          
[EFFECT] System will not be able to add new MAC addresses to the FDB
table.
          
[RECOVERY] Optimize the MAC FDB addresses assigned to different
services.