tmnxPtpClockRecoveryState

TIMETRA-PTP-MIB · .1.3.6.1.4.1.6527.3.1.2.74.3.1.1.9

Object

column Enumeration
The value of tmnxPtpClockRecoveryState indicates the state of the clock
recovery process on a PTP system.  The various states are:
   notApplicable (0) - The system is not attempting to recover a clock
   initial       (1) - The system is configured to recover a clock,
                       but not enough information has yet been received
                       to adjust the local clock to match a master
                       clock
   acquiring     (2) - The system has enough information to attempt
                       clock recovery, and has started the process of
                       adjusting its local clock frequency to match the
                       master clock
   phaseTracking (3) - The system has adjusted its local clock to the
                       approximate frequency of the master clock, and
                       is adjusting the local clock to minimize the
                       phase difference between the two clocks
   holdover      (4) - The system has stopped receiving useful
                       information from the chosen master clock, and is
                       maintaining the last estimated frequency for its
                       local clock
   locked        (5) - The system is locked to the chosen master clock
                       and the phase error between the master clock and
                       the local clock is relatively small

Context

MIB
TIMETRA-PTP-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.74.3.1.1.9
Type
column
Access
readonly
Status
current
Parent
tmnxPtpClockOperEntry
Table
tmnxPtpClockOperTable
Siblings
10

Syntax

Enumeration

Values & Constraints

Enumerated Values
0notApplicable
1initial
2acquiring
3phaseTracking
4holdover
5locked

Related Objects

Sibling Objects