tmnxOFFlowEntryInsertFailed

TIMETRA-OPEN-FLOW-MIB · .1.3.6.1.4.1.6527.3.1.3.93.0.1

Object

notification
[CAUSE] The tmnxOFFlowEntryInsertFailed notification is generated when
a flow-entry could not be inserted into an open-flow table.
          
[EFFECT] The flow-entry won't be available in the flow-table. If
inserting of a default flow-entry failed, then the value of
tmnxOFFlowTableOperStatus is set to 'outOfService (3)'.
          
[RECOVERY] In order to insert the failed flow-entry into flow-table is
to change the admin state of an open-flow switch instance to
'outOfService (3)' and then back to 'inService (1)' and try inserting
the flow-entry again.

Context

MIB
TIMETRA-OPEN-FLOW-MIB
OID
.1.3.6.1.4.1.6527.3.1.3.93.0.1
Type
notification
Status
current
Parent
tmnxOpenFlowNotification

Syntax

No syntax metadata recorded.

Values & Constraints

No enumerated values or constraints recorded.

Related Objects

Notification Objects