tmnxOamEthCfmPingCtlRemoteMepId
TIMETRA-OAM-TEST-MIB ·
.1.3.6.1.4.1.6527.3.1.2.11.1.23.1.5
Object
The value of tmnxOamEthCfmPingCtlRemoteMepId specifies the remote
Maintenance association End Point Identifier (MEP ID) for the test.
A non-zero unicast destination MAC address is required in each test frame
sent for the test. The destination MAC address can be specified directly
(using tmnxOamEthCfmPingCtlTgtMacAddr) or indirectly (using this
object).
Exactly one of tmnxOamEthCfmPingCtlTgtMacAddr and
tmnxOamEthCfmPingCtlRemoteMepId must be assigned a non-default value.
Otherwise, an attempt to administratively enable the test (using
tmnxOamSaaCtlAdminStatus) will fail.
Suppose this object is assigned a non-default value. Then, at the
start of each test run, SROS reads
TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmLearnedRmtMacAddr to find the
destination MAC address to use for the test run.
The following index values are used for the read:
tmnxOamEthCfmPingCtlSrcMdIndex,
tmnxOamEthCfmPingCtlSrcMaIndex,
tmnxOamEthCfmPingCtlSrcMepId,
tmnxOamEthCfmPingCtlRemoteMepId.
If a destination MAC address is not found, no test frames will be sent
for the test run. The number of frames to be sent during a test run is
configured using tmnxOamPingCtlProbeCount.
Configuring tmnxOamEthCfmPingCtlRemoteMepId (instead of
tmnxOamEthCfmPingCtlDestMacAddr) has the following advantage: if the
hardware hosting the test's far end is replaced (meaning a new
destination MAC address is present), the test does not need to be
reconfigured.
Context
- MIB
- TIMETRA-OAM-TEST-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.11.1.23.1.5- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- tmnxOamEthCfmPingCtlEntry
- Table
- tmnxOamEthCfmPingCtlTable
- Siblings
- 4
Syntax
IEEE8021-CFM-MIBDot1agCfmMepIdOrZero
- Source
- IEEE8021-CFM-MIBDot1agCfmMepIdOrZero
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..8191
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| tmnxOamEthCfmPingCtlTgtMacAddr The value of tmnxOamEthCfmPingCtlTgtMacAddr specifies the destination
MAC address for the test.
A non-zero unicast destination MAC address is required in each test … | column | SNMPv2-TCMacAddress | .1.3.6.1.4.1.6527.3.1.2.11.1.23.1.1 |
| tmnxOamEthCfmPingCtlSrcMdIndex The value of tmnxOamEthCfmPingCtlSrcMdIndex specifies the source CFM
maintenance domain index for the test. Zero is the null CFM
maintenance domain index. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.6527.3.1.2.11.1.23.1.2 |
| tmnxOamEthCfmPingCtlSrcMaIndex The value of tmnxOamEthCfmPingCtlSrcMaIndex specifies the source CFM
maintenance association index for the test. Zero is the null CFM
maintenance association index. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.6527.3.1.2.11.1.23.1.3 |
| tmnxOamEthCfmPingCtlSrcMepId The value of tmnxOamEthCfmPingCtlSrcMepId specifies the source
Maintenance association End Point Identifier (MEP ID) for the test.
Zero is the null MEP ID. | column | IEEE8021-CFM-MIBDot1agCfmMepIdOrZero | .1.3.6.1.4.1.6527.3.1.2.11.1.23.1.4 |