tmnxOamDiagTestCompleted

TIMETRA-OAM-TEST-MIB · .1.3.6.1.4.1.6527.3.1.3.11.6.0.1

Object

notification
[CAUSE] A tmnxOamDiagTestCompleted trap is generated at the end of
every diagnostic test run.  A diagnostic test is configured using
tmnxOamDiagCtlTable.
          
tmnxOamDiagCtlTestMode indicates the type of the diagnostic test (e.g.
'findEgressDiag(1)').
          
tmnxOamTestRunIndex indicates the run number of the completed
diagnostic test run.  For example, the second run of a test with owner
'owner_A' and test 'test_Z' has tmnxOamTestRunIndex=2.
          
[EFFECT] The result of the test run can be read (e.g. from the
indicated row in tmnxOamFindEgrDiagResultsTable).
          
[RECOVERY] No recovery is required.