tmnxOamPmStsLossLmmUndetDelTsBwd

TIMETRA-OAM-PM-MIB · .1.3.6.1.4.1.6527.3.1.2.92.2.2.9.1.24

Object

column SNMPv2-SMICounter32
The value of tmnxOamPmStsLossLmmUndetDelTsBwd indicates the number of
undetermined MEF-35 'delta_t's (also known as 'Small Time Intervals')
for the backward direction for the specified measurement interval data
set.
              
An undetermined delta_t occurs when no Loss Measurement Reply (LMR)
PDUs are received during the time interval.
              
This counter is incremented because of a problem with the data path, or
because the MEF-35 delta_t for this test is too short.  delta_t is
configured using tmnxOamPmCfgLossLmmInterval and
tmnxOamPmCfgLossLmmTxFrmsPerDelT.

Context

MIB
TIMETRA-OAM-PM-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.92.2.2.9.1.24
Type
column
Access
readonly
Status
current
Parent
tmnxOamPmStsLossLmmEntry
Table
tmnxOamPmStsLossLmmTable
Siblings
23

Syntax

SNMPv2-SMICounter32
Source
SNMPv2-SMICounter32
Base type
Unsigned32

Values & Constraints

Type Constraints
range: 0..4294967295

Related Objects

Sibling Objects