tmnxOamPmCfgThrLossAvgFlrClear
TIMETRA-OAM-PM-MIB ·
.1.3.6.1.4.1.6527.3.1.2.92.1.3.13.1.4
Object
column
r/w
milli-percent Integer32
The value of tmnxOamPmCfgThrLossAvgFlrClear specifies the clear
threshold for the average Frame Loss Ratio (FLR).
Depending on the specified indices, tmnxOamPmCfgThrLossAvgFlrClear is
the clear threshold for:
tmnxOamPmStsLossSlmAvgFlrFwd,
tmnxOamPmStsLossSlmAvgFlrBwd,
tmnxOamPmStsLossLmmAvgFlrFwd,
tmnxOamPmStsLossLmmAvgFlrBwd,
tmnxOamPmStsLossTwlAvgFlrFwd, or
tmnxOamPmStsLossTwlAvgFlrBwd.
For example, suppose:
1. OAM-PM loss TCAs are enabled for the 'mi15minutes(2)' measurement
interval of the OAM-PM session OAM_PM_Eth_session_1 (using
tmnxOamPmCfgMeasIntvlLossTCAs and tmnxOamPmCfgMeasIntvlTCAs).
2. tmnxOamPmCfgThrLossAvgFlrClear is set to 4000 (i.e. 4.000%) for the
indices {OAM_PM_Eth_session_1, 'slm(2)', 'forward(1)'}.
3. A previous 15 minute interval belonging to OAM_PM_Eth_session_1's
SLM test generated an average FLR Raise TCA for the forward direction
(see tmnxOamPmCfgThrLossAvgFlrRaise). The TCA has not been cleared.
4. The just-closed 15-minute interval has an average forward FLR for
the forward direction (i.e. tmnxOamPmStsLossSlmAvgFlrFwd) of 4000 (i.e.
4.000%), or less.
Then, SROS generates an average FLR Clear TCA (using
tmnxOamPmThrClear) at the end of the 15-minute interval, for the
forward direction.
If tmnxOamPmCfgThrLossAvgFlrRaise > 0 AND
tmnxOamPmCfgThrLossAvgFlrClear >= 0, average FLR Clear TCAs can be
generated for the specified indices. In this case, the maximum number
of average FLR TCAs that will be generated for the specified indices
across (for example) two 15 minute intervals is two: Raise and Clear.
If tmnxOamPmCfgThrLossAvgFlrRaise > 0 AND
tmnxOamPmCfgThrLossAvgFlrClear = -1, no average FLR Clear TCAs
will be generated for the specified indices. In this case, the maximum
number of average FLR TCAs that will be generated for the specified
indices across (for example) two 15 minute intervals is two: Raise and
Raise.
tmnxOamPmCfgThrLossAvgFlrRaise must be greater than
tmnxOamPmCfgThrLossAvgFlrClear. Exception: the combination
tmnxOamPmCfgThrLossAvgFlrRaise=-1 and tmnxOamPmCfgThrLossAvgFlrClear=-1
is supported.
tmnxOamPmCfgThrLossAvgFlrClear and tmnxOamPmCfgThrLossAvgFlrClear must
be set in the same SNMP Set PDU.
Context
- MIB
- TIMETRA-OAM-PM-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.92.1.3.13.1.4- Type
- column
- Access
- readwrite
- Status
- current
- Units
- milli-percent
- Parent
- tmnxOamPmCfgThrLossFwBwEntry
- Table
- tmnxOamPmCfgThrLossFwBwTable
- Siblings
- 3
Syntax
milli-percent Integer32
Values & Constraints
Object Constraints
range: -1-99999
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| tmnxOamPmCfgTestType The value of tmnxOamPmCfgTestType specifies the test type index of the
row.
The test types supporting loss thresholds are 'slm(2)',
'twampLight(3)', and 'lmm(4)'. | column | TmnxOamPmTestType | .1.3.6.1.4.1.6527.3.1.2.92.1.3.13.1.1 |
| tmnxOamPmCfgForwardBackward The value of tmnxOamPmCfgForwardBackward specifies the direction index
of the row. | column | TmnxOamPmForwardBackward | .1.3.6.1.4.1.6527.3.1.2.92.1.3.13.1.2 |
| tmnxOamPmCfgThrLossAvgFlrRaise The value of tmnxOamPmCfgThrLossAvgFlrRaise specifies the raise
threshold for the average Frame Loss Ratio (FLR).
Depending on the specified indices, tmnxOamPmCfgTh… | column | milli-percent Integer32 | .1.3.6.1.4.1.6527.3.1.2.92.1.3.13.1.3 |