tmnxOamPmCfgLossLmmTxFrmsPerDelT

TIMETRA-OAM-PM-MIB · .1.3.6.1.4.1.6527.3.1.2.92.1.3.12.1.8

Object

column r/w frames Unsigned32
The value of tmnxOamPmCfgLossLmmTxFrmsPerDelT specifies the number of
LMM frames to send in one MEF-35 'delta_t' (also known as 'Small Time
Interval') when computing availability statistics for the specified
session's LMM test.
              
The availability parameters used by SROS for LMM tests (e.g.
tmnxOamPmCfgLossLmmTxFrmsPerDelT) are modelled after the MEF-35
availability parameters defined for Synthetic Loss Measurement (SLM)
tests.  Hence, the REFERENCE text for this object is a MEF-35 SLM
section.
              
Expressed in milliseconds,
delta_t =
   tmnxOamPmCfgLossLmmTxFrmsPerDelT *
   tmnxOamPmCfgLossLmmInterval.

Context

MIB
TIMETRA-OAM-PM-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.92.1.3.12.1.8
Type
column
Access
readwrite
Status
current
Units
frames
Parent
tmnxOamPmCfgLossLmmEntry
Table
tmnxOamPmCfgLossLmmTable
Siblings
13

Syntax

frames Unsigned32