vRtrMplsTpPtcTmplProtectionMode
TIMETRA-MPLS-TP-MIB ·
.1.3.6.1.4.1.6527.3.1.2.83.2.2.2.1.4
Object
column
r/w
Enumeration
The value of vRtrMplsTpPtcTmplProtectionMode specifies the mode used
for determining which members are actively receiving and transmitting
data.
In the 'one2one (1)' (1:1) architecture, a protection transport path
is dedicated to the working transport path of a single service, and
the traffic is only transmitted on either the working or the
protection path, by using a selector at the source of the protection
domain. A selector at the sink of the protection domain then selects
the path that carries the normal traffic.
When the value is set to 'one2one (1)', only two members are allowed,
and only one of them can be active at one point in time.
Context
- MIB
- TIMETRA-MPLS-TP-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.83.2.2.2.1.4- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- vRtrMplsTpPtcTemplateCfgEntry
- Table
- vRtrMplsTpPtcTemplateCfgTable
- Siblings
- 8
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | one2one |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vRtrMplsTpPtcTmplName The value of vRtrMplsTpPtcTmplName specifies the unique name of the
MPLS-TP Protection Template. | column | TIMETRA-TC-MIBTNamedItem | .1.3.6.1.4.1.6527.3.1.2.83.2.2.2.1.1 |
| vRtrMplsTpPtcTmplRowStatus The value of vRtrMplsTpPtcTmplRowStatus specifies the row status of
the MPLS-TP Protection Template.
Rows are created by setting this object to the value 'createAnd… | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.6527.3.1.2.83.2.2.2.1.2 |
| vRtrMplsTpPtcTmplLastChangedTime The value of vRtrMplsTpPtcTmplLastChangedTime indicates the time,
since system startup, that a columnar object in the MPLS-TP Protection
Template entry last changed state. | column | SNMPv2-TCTimeStamp | .1.3.6.1.4.1.6527.3.1.2.83.2.2.2.1.3 |
| vRtrMplsTpPtcTmplProtectionDir The value of vRtrMplsTpPtcTmplProtectionDir specifies the directional
mode of the Protection Template.
bidirectional - provides protection in both directions. | column | Enumeration | .1.3.6.1.4.1.6527.3.1.2.83.2.2.2.1.5 |
| vRtrMplsTpPtcTmplRevertive The value of vRtrMplsTpPtcTmplRevertive specifies whether or not an
instance of this Template will operate in a 'revertive (2)' or
'nonRevertive (1)' mode. | column | Enumeration | .1.3.6.1.4.1.6527.3.1.2.83.2.2.2.1.6 |
| vRtrMplsTpPtcTmplWaitToRestore The value of vRtrMplsTpPtcTmplWaitToRestore specifies the
Wait-To-Restore (WTR) timer, in seconds, after a cleared failure the
working path must wait before reverting.
… | column | seconds Unsigned32 | .1.3.6.1.4.1.6527.3.1.2.83.2.2.2.1.7 |
| vRtrMplsTpPtcTmplRapidPscTimer The value of vRtrMplsTpPtcTmplRapidPscTimer specifies the time, in
milliseconds, for the Rapid Protection Switch Coordination (PSC)
timer.
When the protection domai… | column | milliseconds Unsigned32 | .1.3.6.1.4.1.6527.3.1.2.83.2.2.2.1.8 |
| vRtrMplsTpPtcTmplSlowPscTimer The value of vRtrMplsTpPtcTmplSlowPscTimer specifies the time, in
seconds, for the Slow Protection Switch Coordination (PSC) timer used
to continually transmit the PSC message. | column | seconds Unsigned32 | .1.3.6.1.4.1.6527.3.1.2.83.2.2.2.1.9 |