vRtrMplsLspTempAutoBWAdjUPPer

TIMETRA-MPLS-MIB · .1.3.6.1.4.1.6527.3.1.2.6.47.1.4

Object

column r/w percent Unsigned32
The value of vRtrMplsLspTempAutoBWAdjUPPer specifies minimum
difference between the current bandwidth reservation of the LSP
template and the (measured) maximum average data rate, expressed as a
percentage of the current bandwidth, for increasing the bandwidth of
the LSP template. At the adjust interval expiry, if the measured
bandwidth exceeds the current bandwidth by the value of
vRtrMplsLspTempAutoBWAdjUPPer it can cause a resignaling attempt for
the LSP template.
              
When the value of vRtrMplsLspTempAutoBWAdjUPPer is 0 it means that
this threshold check is always true for any measured bandwidth greater
than current bandwidth

Context

MIB
TIMETRA-MPLS-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.6.47.1.4
Type
column
Access
readwrite
Status
current
Units
percent
Parent
vRtrMplsLspTempAutoBWEntry
Table
vRtrMplsLspTempAutoBWTable
Siblings
25

Syntax

percent Unsigned32

Values & Constraints

Object Constraints
range: 0-100

Related Objects

Sibling Objects