tmnxMobServBcRfServerAddrType
TIMETRA-MOBILE-SERVING-MIB ·
.1.3.6.1.4.1.6527.3.1.2.66.2.5.1.44
Object
column
INET-ADDRESS-MIBInetAddressType
The value of tmnxMobServBcRfServerAddrType indicates the type of
address represented by tmnxMobServBcRfServerAddr.
The value of this object is valid only if the value of
tmnxMobServPcRfChargingLevel is equal to 'bearer'.
Context
- MIB
- TIMETRA-MOBILE-SERVING-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.66.2.5.1.44- Type
- column
- Access
- readonly
- Status
- current
- Parent
- tmnxMobServBearerContextEntry
- Table
- tmnxMobServBearerContextTable
- Siblings
- 49
Syntax
INET-ADDRESS-MIBInetAddressType
- Source
- INET-ADDRESS-MIBInetAddressType
- Base type
Enumeration
Values & Constraints
Type Values
0 | unknown |
1 | ipv4 |
2 | ipv6 |
3 | ipv4z |
4 | ipv6z |
16 | dns |
25 | l2vpn |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| tmnxMobServBcBearerId The value of tmnxMobServBcBearerId indicates the bearer id which
uniquely identifies a bearer context in a Packet Data Network (PDN)
context. | column | TIMETRA-TC-MG-MIBTmnxMobBearerId | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.1 |
| tmnxMobServBcQosUlGbr The value of tmnxMobServBcQosUlGbr indicates the uplink Guaranteed
Bit Rate (GBR) for this bearer. | column | Kbps SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.10 |
| tmnxMobServBcQosDlGbr The value of tmnxMobServBcQosDlGbr indicates the downlink
Guaranteed Bit Rate (GBR) for this bearer. | column | Kbps SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.11 |
| tmnxMobServBcS1uEnodebTeid The value of tmnxMobServBcS1uEnodebTeid indicates the Tunnel Endpoint
Identifier (TEID) of the Evolved NodeB (eNodeB) on the S1-U
reference point. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.12 |
| tmnxMobServBcS1uEnodebAddrType The value of tmnxMobServBcS1uEnodebAddrType indicates the type of
address represented by tmnxMobServBcS1uEnodebAddr. | column | INET-ADDRESS-MIBInetAddressType | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.13 |
| tmnxMobServBcS1uEnodebAddr The value of tmnxMobServBcS1uEnodebAddr indicates the IP address of
the Evolved NodeB (eNodeB) on the S1-U reference point. | column | OctetString | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.14 |
| tmnxMobServBcS1uSgwTeid The value of tmnxMobServBcS1uSgwTeid indicates the Tunnel Endpoint
Identifier (TEID) of the Serving Gateway (SGW) on S1-U reference
point. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.15 |
| tmnxMobServBcS1uSgwAddrType The value of tmnxMobServBcS1uSgwAddrType indicates the type of
address represented by tmnxMobServBcS1uSgwAddr. | column | INET-ADDRESS-MIBInetAddressType | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.16 |
| tmnxMobServBcS1uSgwAddr The value of tmnxMobServBcS1uSgwAddr indicates the IP address of
the Serving Gateway (SGW) on S1-U reference point. | column | OctetString | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.17 |
| tmnxMobServBcS5S8SgwTeid The value of tmnxMobServBcS5S8SgwTeid indicates the Tunnel Endpoint
Identifier (TEID) of the Serving Gateway (SGW) on the S5 or S8
reference point. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.18 |
| tmnxMobServBcS5S8SgwDataAddrType The value of tmnxMobServBcS5S8SgwDataAddrType indicates the type of
address represented by tmnxMobServBcS5S8SgwDataAddr. | column | INET-ADDRESS-MIBInetAddressType | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.19 |
| tmnxMobServBcBearerType The value of tmnxMobServBcBearerType indicates the type of this
bearer. | column | TIMETRA-TC-MG-MIBTmnxMobBearerType | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.2 |
| tmnxMobServBcS5S8SgwDataAddr The value of tmnxMobServBcS5S8SgwDataAddr indicates the IP address of
the Serving Gateway (SGW) on the S5 or S8 reference point. | column | OctetString | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.20 |
| tmnxMobServBcS5S8PgwTeid The value of tmnxMobServBcS5S8PgwTeid indicates the Tunnel Endpoint
Identifier (TEID) of the Packet Data Network Gateway (PGW) on the S5
or S8 reference point. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.21 |
| tmnxMobServBcS5S8PgwDataAddrType The value of tmnxMobServBcS5S8PgwDataAddrType indicates the type of
address represented by tmnxMobServBcS5S8PgwDataAddr. | column | INET-ADDRESS-MIBInetAddressType | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.22 |
| tmnxMobServBcS5S8PgwDataAddr The value of tmnxMobServBcS5S8PgwDataAddr indicates the IP address of
the Packet Data Network Gateway (PGW) on the S5 or S8 reference point. | column | OctetString | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.23 |
| tmnxMobServBcS11QosModifications The value of tmnxMobServBcS11QosModifications indicates the number of
S11 QoS modifications. | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.24 |
| tmnxMobServBcS5ULPackets The value of tmnxMobServBcS5ULPackets indicates the number of
S5 uplink packets. | column | SNMPv2-SMICounter64 | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.25 |
| tmnxMobServBcS5ULBytes The value of tmnxMobServBcS5ULBytes indicates the number of
S5 uplink bytes. | column | SNMPv2-SMICounter64 | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.26 |
| tmnxMobServBcS1uDLPackets The value of tmnxMobServBcS1uDLPackets indicates the number of
S1-U downlink packets. | column | SNMPv2-SMICounter64 | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.27 |
| tmnxMobServBcS1uDLBytes The value of tmnxMobServBcS1uDLBytes indicates the number of
S1-U downlink bytes. | column | SNMPv2-SMICounter64 | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.28 |
| tmnxMobServBcS5ULPacketsLow The value of tmnxMobServBcS5ULPacketsLow indicates the lower 32 bits
of the value of tmnxMobServBcS5ULPackets. | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.29 |
| tmnxMobServBcUpTime The value of tmnxMobServBcUpTime indicates the time, in seconds,
since this bearer context was created. | column | seconds SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.3 |
| tmnxMobServBcS5ULPacketsHigh The value of tmnxMobServBcS5ULPacketsHigh indicates the higher 32
bits of the value of tmnxMobServBcS5ULPackets. | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.30 |
| tmnxMobServBcS5ULBytesLow The value of tmnxMobServBcS5ULBytesLow indicates the lower 32 bits
of the value of tmnxMobServBcS5ULBytes. | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.31 |
| tmnxMobServBcS5ULBytesHigh The value of tmnxMobServBcS5ULBytesHigh indicates the higher 32
bits of the value of tmnxMobServBcS5ULBytes. | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.32 |
| tmnxMobServBcS1uDLPacketsLow The value of tmnxMobServBcS1uDLPacketsLow indicates the lower 32 bits
of the value of tmnxMobServBcS1uDLPackets. | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.33 |
| tmnxMobServBcS1uDLPacketsHigh The value of tmnxMobServBcS1uDLPacketsHigh indicates the higher 32
bits of the value of tmnxMobServBcS1uDLPackets. | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.34 |
| tmnxMobServBcS1uDLBytesLow The value of tmnxMobServBcS1uDLBytesLow indicates the lower 32 bits
of the value of tmnxMobServBcS1uDLBytes. | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.35 |
| tmnxMobServBcS1uDLBytesHigh The value of tmnxMobServBcS1uDLBytesHigh indicates the higher 32
bits of the value of tmnxMobServBcS1uDLBytes. | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.36 |
| tmnxMobServBcSetupLatencyTime The value of tmnxMobServBcSetupLatencyTime indicates the setup
latency time in this bearer context. | column | milliseconds SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.37 |
| tmnxMobServBcIndTnlRemTeid The value of tmnxMobServBcIndTnlRemTeid indicates the Tunnel Endpoint
Identifier (TEID) of the far end in the indirect tunnel created during
S1 handover. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.38 |
| tmnxMobServBcIndTnlRemAddrType The value of tmnxMobServBcIndTnlRemAddrType indicates the type of
address represented by tmnxMobServBcIndTnlRemAddr. | column | INET-ADDRESS-MIBInetAddressType | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.39 |
| tmnxMobServBcQci The value of tmnxMobServBcQci indicates the Qos Class Identifier of
this bearer context. The value of this object is used as a reference
to access node-specific parameters that co… | column | TIMETRA-TC-MG-MIBTmnxMobQci | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.4 |
| tmnxMobServBcIndTnlRemAddr The value of tmnxMobServBcIndTnlRemAddr indicates the IP address of
the far end in the indirect tunnel created during S1 handover. | column | OctetString | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.40 |
| tmnxMobServBcIndTnlLocalTeid The value of tmnxMobServBcIndTnlLocalTeid indicates the Tunnel Endpoint
Identifier (TEID) of the local endpoint in the indirect
tunnel created during S1 handover. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.41 |
| tmnxMobServBcIndTnlLocalAddrType The value of tmnxMobServBcIndTnlLocalAddrType indicates the type of
address represented by tmnxMobServBcIndTnlLocalAddr. | column | INET-ADDRESS-MIBInetAddressType | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.42 |
| tmnxMobServBcIndTnlLocalAddr The value of tmnxMobServBcIndTnlLocalAddr indicates the IP address of
the local endpoint in the indirect tunnel created during S1 handover. | column | OctetString | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.43 |
| tmnxMobServBcRfServerAddr The value of tmnxMobServBcRfServerAddr indicates the charging server
address on the Rf reference point.
The value of this object is valid only if the value of
tmnx… | column | OctetString | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.45 |
| tmnxMobServBcRfServerState The value of tmnxMobServBcRfServerState indicates the charging server
state on the Rf reference point.
The value of this object is valid only if the value of
tmnxM… | column | TIMETRA-TC-MG-MIBTmnxMobServerState | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.46 |
| tmnxMobServBcRfChargingProfile The value of tmnxMobServBcRfChargingProfile indicates the charging
profile used on the Rf reference point.
The value of this object is valid only if the value of
… | column | TIMETRA-TC-MG-MIBTmnxMobChargingProfile | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.47 |
| tmnxMobServBcRfTriggeredRecords The value of tmnxMobServBcRfTriggeredRecords indicates the number of
records generated by triggers on the Rf reference point.
The value of this object is valid onl… | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.48 |
| tmnxMobServBcRfInterimRecords The value of tmnxMobServBcRfInterimRecords indicates the number of
interim records sent on the Rf reference point.
The value of this object is valid only if the val… | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.49 |
| tmnxMobServBcArp The value of tmnxMobServBcArp indicates the Allocation and Retention
Priority (ARP) of this bearer context. The value of this object gives
information about the priority level, th… | column | TIMETRA-TC-MG-MIBTmnxMobArp | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.5 |
| tmnxMobServBcRefPointType The value of tmnxMobServBcRefPointType indicates the reference point
type for the bearer context of an User Equipment (UE). | column | TIMETRA-TC-MG-MIBTmnxMobServRefPointType | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.50 |
| tmnxMobServBcSdfs The value of tmnxMobServBcSdfs indicates the number of Service Data
Flows (SDFs) in this bearer context. | column | TIMETRA-TC-MG-MIBTmnxMobSdf | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.6 |
| tmnxMobServBcFilters The value of tmnxMobServBcFilters indicates the number of IP filters
in this bearer context. | column | TIMETRA-TC-MG-MIBTmnxMobSdfFilterNum | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.7 |
| tmnxMobServBcQosUlMbr The value of tmnxMobServBcQosUlMbr indicates the uplink Maximum
Bit Rate (MBR) for this bearer. | column | Kbps SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.8 |
| tmnxMobServBcQosDlMbr The value of tmnxMobServBcQosDlMbr indicates the downlink Maximum
Bit Rate (MBR) for this bearer. | column | Kbps SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.6527.3.1.2.66.2.5.1.9 |