tmnxMcRingNodeLocOperStateChgd

TIMETRA-MC-REDUNDANCY-MIB · .1.3.6.1.4.1.6527.3.1.3.40.0.18

Object

notification
[CAUSE] The notification tmnxMcRingNodeLocOperStateChgd is generated
upon a change of the operational state of a provisioned ring node as
monitored by the local chassis, or when an unprovisioned ring
node appears or disappears. unknown : none
notProvisioned : the node is configured on the peer but not on this
system; configErr : the local configuration of the node is incorrect
notTested : the ring node connectivity verification is shut down;
testing : temporary state; connected : none disconnected : none
          
[EFFECT] unknown : none notProvisioned : no effect; configErr :
no effect; notTested : no effect; testing : no effect; the effect of
the operational state of the ring node depends on the operational
state of the ring; only when the operational state of the ring is
'broken'. connected : ... all MAC addresses associated with this ring
node are put on the SAP; disconnected : ... all MAC addresses
associated with this ring node are put on the shunt;
          
[RECOVERY] Recovery is only required if the operational state of the
ring is 'broken'. Repair the ring connection with the peer.