tmnxL2tpTgCfgHelloInterval

TIMETRA-L2TP-MIB · .1.3.6.1.4.1.6527.3.1.2.60.1.2.1.2.1.7

Object

column r/w seconds TmnxL2tpTunnelHelloInterval
The value of tmnxL2tpTgCfgHelloInterval specifies the time interval
between two consecutive tunnel Hello messages.
              
A value of '-1' specifies that the keepalive function is disabled.
              
A value of '-2' specifies that the value must be set to the actual
value of the object tmnxL2tpHelloInterval.

Context

MIB
TIMETRA-L2TP-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.60.1.2.1.2.1.7
Type
column
Access
readwrite
Status
current
Units
seconds
Parent
tmnxL2tpTgCfgEntry
Table
tmnxL2tpTgCfgTable
Siblings
22

Syntax

seconds TmnxL2tpTunnelHelloInterval
Source
TmnxL2tpTunnelHelloInterval
Base type
Integer32

Values & Constraints

Type Constraints
range: -2..-1 range: 10..3600