tmnxIsisReferenceBwU64Low

TIMETRA-ISIS-NG-MIB · .1.3.6.1.4.1.6527.3.1.2.88.1.11.1.53

Object

column r/w kilobps TIMETRA-TC-MIBTmnxLow32
The value of the object tmnxIsisReferenceBwU64Low specifies the lower
32 bit of the reference bandwidth that needs to be used to calculate
the cost.
              
This value should always be set along with tmnxIsisReferenceBwU64High,
otherwise an 'inconsistentValue' error is returned.
              
In order to calculate the lowest cost to reach a given destination
each configured level on each interface must have a cost.
              
If the reference-bandwidth is defined then the cost is calculated
using the following formula:
    Cost = reference-bandwidth / bandwidth.
              
If the reference bandwidth is configured as Ten Gig (10,000,000,000) a
100-Mbps interface has a default metric of 100. In order for metrics
in excess of 63 to be configured wide metrics must be deployed.
              
A value of '0' means that the reference bandwidth is not defined.

Context

MIB
TIMETRA-ISIS-NG-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.88.1.11.1.53
Type
column
Access
readwrite
Status
current
Units
kilobps
Parent
tmnxIsisExtEntry
Table
tmnxIsisExtTable
Siblings
67

Syntax

kilobps TIMETRA-TC-MIBTmnxLow32
Source
TIMETRA-TC-MIBTmnxLow32
Base type
Unsigned32

Values & Constraints

No enumerated values or constraints recorded.

Related Objects

Sibling Objects