tmnxEthTunnelRevertTime
TIMETRA-ETH-TUNNEL-MIB ·
.1.3.6.1.4.1.6527.3.1.2.64.1.1.1.6
Object
column
r/w
seconds Unsigned32
The value of tmnxEthTunnelRevertTime specifies the time, in seconds,
that the tunnel waits to restore the working member.
A value of zero (0) sets the behavior of the Ethernet Tunnel Group to
be non-revertive, while a positive value specifies the wait time.
After clearing of a condition that necessitated an automatic switch,
the wait to restore period, indicated by reading the
tmnxEthTunnelRevertTimeCountDn object, must elapse before reverting.
This is intended to avoid rapid switch oscillations.
This object is only applicable when the tmnxEthTunnelProtectionType is
set to 'g8031-1to1 (1)'.
Context
- MIB
- TIMETRA-ETH-TUNNEL-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.64.1.1.1.6- Type
- column
- Access
- readwrite
- Status
- current
- Units
- seconds
- Parent
- tmnxEthTunnelConfigEntry
- Table
- tmnxEthTunnelConfigTable
- Siblings
- 6
Syntax
seconds Unsigned32
Values & Constraints
Object Constraints
range: 0-720
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| tmnxEthTunnelIndex The tmnxEthTunnelIndex specifies the row index of the Ethernet Tunnel
Group. | column | Unsigned32 | .1.3.6.1.4.1.6527.3.1.2.64.1.1.1.1 |
| tmnxEthTunnelRowStatus The tmnxEthTunnelRowStatus controls the creation and deletion of row
entries in the tmnxEthTunnelConfigTable.
A corresponding row in the tmnxPortTable is created by… | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.6527.3.1.2.64.1.1.1.2 |
| tmnxEthTunnelTimeStamp The tmnxEthTunnelTimeStamp indicates the time, since system startup,
of the last change to this row. | column | SNMPv2-TCTimeStamp | .1.3.6.1.4.1.6527.3.1.2.64.1.1.1.3 |
| tmnxEthTunnelHoldDownTimeMember The value of tmnxEthTunnelHoldDownTimeMember specifies the time, in
centiseconds, used for the hold-timer for associated Continuity Check
(CC) Session down event dampening. This g… | column | centiseconds Unsigned32 | .1.3.6.1.4.1.6527.3.1.2.64.1.1.1.4 |
| tmnxEthTunnelProtectionType The value of tmnxEthTunnelProtectionType specifies the model used for
determining which members are actively receiving and transmitting
data.
When the value is set … | column | Enumeration | .1.3.6.1.4.1.6527.3.1.2.64.1.1.1.5 |
| tmnxEthTunnelHoldUpTimeMember The value of tmnxEthTunnelHoldUpTimeMember specifies the time, in
deciseconds, used for the hold-timer for associated Continuity
Check (CC) Session up event dampening. This guard… | column | deciseconds Unsigned32 | .1.3.6.1.4.1.6527.3.1.2.64.1.1.1.7 |