tmnxEthRingCcmHoldDownTime

TIMETRA-ETH-RING-MIB · .1.3.6.1.4.1.6527.3.1.2.72.1.1.1.10

Object

column r/w centiseconds Unsigned32
The value of tmnxEthRingCcmHoldDownTime specifies the time, in
centiseconds, used for the hold-timer for associated Continuity Check
(CC) Session down event dampening. This guards against reporting
excessive path operational state transitions.
              
This is implemented by not advertising subsequent transitions of the
CC state to the Ethernet Ring Node until the configured timer has
expired.
              
A value of zero (0) specifies that a down transition is reported
immediately.

Context

MIB
TIMETRA-ETH-RING-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.72.1.1.1.10
Type
column
Access
readwrite
Status
current
Units
centiseconds
Parent
tmnxEthRingConfigEntry
Table
tmnxEthRingConfigTable
Siblings
18

Syntax

centiseconds Unsigned32

Values & Constraints

Object Constraints
range: 0-5000

Related Objects