tmnxSfmIcPortSFFRemoved
TIMETRA-CHASSIS-INTERCONNECT-MIB ·
.1.3.6.1.4.1.6527.3.1.3.94.0.3.4
Object
notification
[CAUSE] The tmnxSfmIcPortSFFRemoved notification is generated when the
SFF (e.g. CXP) is removed from the SFM interconnect port.
[EFFECT] Removing the module will cause the port to go down. This
port can no longer be used as part of the user plane fabric between
chassis. Other fabric paths may be available resulting in no loss of
capacity.
[RECOVERY] Insert a working SFF into the SFM interconnect port.
Context
- MIB
- TIMETRA-CHASSIS-INTERCONNECT-MIB
- OID
.1.3.6.1.4.1.6527.3.1.3.94.0.3.4- Type
- notification
- Status
- current
- Parent
- tmnxSfmIcPortNotifications
- Siblings
- 8
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| tmnxSfmIcPortDown [CAUSE] The tmnxSfmIcPortDown alarm is generated when the SFM
interconnect port is not operational. The reason may be a cable
connected incorrectly, a disconnected cable, a faulty… | notification | - | .1.3.6.1.4.1.6527.3.1.3.94.0.3.1 |
| tmnxSfmIcPortUp [CAUSE] The tmnxSfmIcPortUp notification is generated when the SFM
interconnect port is operational again.
[EFFECT] This port can now be used as part of the user plane … | notification | - | .1.3.6.1.4.1.6527.3.1.3.94.0.3.2 |
| tmnxSfmIcPortSFFInserted [CAUSE] The tmnxSfmIcPortSFFInserted notification is generated when
the Small Form Factor (SFF) pluggable optical module (e.g. CXP) is
inserted into an SFM interconnect port.
… | notification | - | .1.3.6.1.4.1.6527.3.1.3.94.0.3.3 |
| tmnxSfmIcPortSFFStatusFailure [CAUSE] The tmnxSfmIcPortSFFStatusFailure notification is generated
when the value of tmnxSfmIcPortSFFStatus results in a value other than
'not-equipped (0)', or 'operational (1)'… | notification | - | .1.3.6.1.4.1.6527.3.1.3.94.0.3.5 |
| tmnxSfmIcPortDDMFailure [CAUSE] The tmnxSfmIcPortDDMFailure notification is generated when an
SFF in an SFM interconnect port that supports Digital Diagnostic
Monitoring (DDM) enters a failed state. | notification | - | .1.3.6.1.4.1.6527.3.1.3.94.0.3.6 |
| tmnxSfmIcPortDDMClear [CAUSE] The tmnxSfmIcPortDDMFailure notification is generated when an
SFF in an SFM interconnect port that supports Digital Diagnostic
Monitoring (DDM) clears a failed state. | notification | - | .1.3.6.1.4.1.6527.3.1.3.94.0.3.7 |
| tmnxSfmIcPortDegraded [CAUSE] The tmnxSfmIcPortDegraded notification is generated when the
system has detected a degradation of the switch fabric that is
associated with a particular SFM interconnect p… | notification | - | .1.3.6.1.4.1.6527.3.1.3.94.0.3.8 |
| tmnxSfmIcPortDegradedClear [CAUSE] The tmnxSfmIcPortDegradedClear notification is generated when
the switch fabric associated with the SFM interconnect port is not
degraded. This occurs when the value of tm… | notification | - | .1.3.6.1.4.1.6527.3.1.3.94.0.3.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| tmnxSfmIcPortSFFEquipped The value of tmnxSfmIcPortSFFEquipped indicates whether or not a small
form factor (SFF) pluggable optical module (e.g. CXP) is inserted into
the SFM interconnect port. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.6527.3.1.2.94.1.2.1.3 |