fsSynceTraceOption
SyncE-MIB ·
.1.3.6.1.4.1.29601.2.79.1.1.2.1.2
Object
This variable governs the trace levels in the SyncE module.
A four byte integer is used for enabling the trace level.
Each bit in the four byte integer represents a particular
trace level.
The mapping between the bit positions & the trace level is
as follows:
Bit 0 - Init and Shutdown traces
Bit 1 - Management traces
Bit 2 - Data Path traces [NOT REQUIRED IN SYNCE]
Bit 3 - Control Plane traces
Bit 4 - Packet Dump traces
Bit 5 - Traces related to all resources except buffers
Bit 6 - All Failure traces
Bit 7 - Buffer allocation/release traces
Bit 16 - SYNCE Function Entry traces
Bit 17 - SYNCE Function Exit traces
Bit 18 - SYNCE Critical traces
The remaining bits are unused. Combination of levels are
also allowed.
For example, if the bits 19 and 20 are set, then the trace
statement related to discovery and remote loopback related
messages will be printed.
The user has to enter the corresponding integer value for the
bits set. For example, if bits 8 and 9 are to be set, then user
has to give the value 0x300.
Context
- MIB
- SyncE-MIB
- OID
.1.3.6.1.4.1.29601.2.79.1.1.2.1.2- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- fsSynceEntry
- Table
- fsSynceTable
- Siblings
- 6
Syntax
SNMPv2-SMIUnsigned32
- Source
- SNMPv2-SMIUnsigned32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| fsSynceContextId This object is a unique context identifier for each entry.
Each virtual context will be able to run SyncE protocol individually
and will be distinguished by this object. | column | Integer32 | .1.3.6.1.4.1.10876.101.2.79.1.1.2.1.1 |
| fsSynceQLMode This object is used to configure QL Enable/Disable mode for
the selection process in SyncE module.
The default value of this object is Enabled.
In the disabled state the quality l… | column | Enumeration | .1.3.6.1.4.1.10876.101.2.79.1.1.2.1.3 |
| fsSynceQLValue This object contains the QL value selected through the clock selection
process. The value of this object shall be used while transmitting the
SSM packets.
If this value is set by … | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.10876.101.2.79.1.1.2.1.4 |
| fsSynceSSMOptionMode This object is used to select Option 1(Europe) or Option 2(America)
clocks in SyncE. | column | Enumeration | .1.3.6.1.4.1.10876.101.2.79.1.1.2.1.5 |
| fsSynceSelectedInterface This object represent the currently selected interface which QL value
is being used for transmitting QL in SSM packets. | column | IF-MIBInterfaceIndex | .1.3.6.1.4.1.10876.101.2.79.1.1.2.1.6 |
| fsSynceContextRowStatus Used for creation/deletion of enteries in the table | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.10876.101.2.79.1.1.2.1.7 |