ccHwSensorsMinimum
SYMBOL-WS5000-MIB ·
.1.3.6.1.4.1.388.6.6.2.2.1.5
Object
column
SNMPv2-SMIGauge32
The minimum reading observed since system reboot, (or since
the fan/temp readings were reset).
For sensors of type onOffFanInDutyCycle, this value will be
the minimum 'duty' cycle of the fan, (ranging 0..100). The
time interval over which the duty cycle is calculated is up
to the switch, but shall be long enough as to provide a
meaningful result.
Context
- MIB
- SYMBOL-WS5000-MIB
- OID
.1.3.6.1.4.1.388.6.6.2.2.1.5- Type
- column
- Access
- readonly
- Status
- current
- Parent
- ccHwSensorsEntry
- Table
- ccHwSensorsTable
- Siblings
- 6
Syntax
SNMPv2-SMIGauge32
- Source
- SNMPv2-SMIGauge32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ccHwSensorsIndex Simple index. | column | Integer32 | .1.3.6.1.4.1.388.6.6.2.2.1.1 |
| ccHwSensorsType Tells the type of the fan or temp sensor, and the
corresponding units for the readings.
Note that any given temp sensors appears in this table only
once; (NOT twi… | column | Enumeration | .1.3.6.1.4.1.388.6.6.2.2.1.2 |
| ccHwSensorsDescr A short, text description of the sensor.
For example:
'system fan'
'CPU fan/blower'
'CPU temperature'
'ambient temperature - near CPU'
'ambient temperatur… | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.388.6.6.2.2.1.3 |
| ccHwSensorsCurrentReading The current, live reading for that sensor.
For sensors of type onOffFanInDutyCycle, this value will be
0 if the fan is currently not running, and 1 if the fan is
r… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.388.6.6.2.2.1.4 |
| ccHwSensorsMaximum The maximum observed since system reboot, (or since
the fan/temp readings were reset).
For sensors of type onOffFanInDutyCycle, this value will be
the maximum 'dut… | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.388.6.6.2.2.1.6 |
| ccHwSensorsNotifyIfAbove When the given sensor's reading exceeds this threshold, a
notification is generated.
If no notifications are desired for this sensor, set this
threshold to 0.