ccResetFactory
SYMBOL-CC-WS2000-MIB ·
.1.3.6.1.4.1.388.11.2.2.2.1
Object
Writing this value causes the switch to reset to
factory conditions. NOTHING is retained, NOT the
static IP address assignments (if any), NOR any
non-factory-default SNMP settings, nor any other
non-factory-default settings.
Given this, be warned that setting this value may
very well cause all communication paths to the
WS2000 to be lost. (However, if DHCP is used to
obtain an IP addr on the WAN port, and only
default SNMP settings are used, communications may
be possible after the factory reset).
Context
- MIB
- SYMBOL-CC-WS2000-MIB
- OID
.1.3.6.1.4.1.388.11.2.2.2.1- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- ccReset
- Siblings
- 4
Values & Constraints
Type Values
1 | true |
2 | false |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ccResetSwitch Writing this value causes the switch to reset in
the same fashion as a common, (non-factory) reset. | scalar | SNMPv2-TCTruthValue | .1.3.6.1.4.1.388.11.2.2.2.2 |
| ccResetMuCounters obsolete Writing this value resets all counters in the
ccRf > ccMus sub-tree.
Obsolete in WS2000 v1.5 | scalar | SNMPv2-TCTruthValue | .1.3.6.1.4.1.388.11.2.2.2.3 |
| ccResetFactoryExceptIpSnmp Performs a factory reset, EXCEPT that Wan IP and SNMP access settings
are retained across the reset. Specifically:
Wan Ip + related settings
Pppoe settings
WS2000 wan … | scalar | DoActionNow | .1.3.6.1.4.1.388.11.2.2.2.4 |
| ccResetStatCounters Writing this value resets all counters in the
ccRf sub-tree except for the ccPortalSystemStatsTable and
ccPortalTable | scalar | SNMPv2-TCTruthValue | .1.3.6.1.4.1.388.11.2.2.2.5 |