ccRapPollOneMuMac
SYMBOL-CC-WS2000-MIB ·
.1.3.6.1.4.1.388.11.2.7.4.2.1
Object
Writing this value with the MAC address of a MU
causes the switch to read that MU's known AP list.
This read is performed just once, (it is not repeated).
This read occurs regardless of the state of
ccRapPollSymbolMusEnable. The read is also performed
immediately - the switch does NOT wait until the next
Sybmol MU poll interval, (as specified in
ccRapPollSymbolMusInterval).
Context
- MIB
- SYMBOL-CC-WS2000-MIB
- OID
.1.3.6.1.4.1.388.11.2.7.4.2.1- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- ccRapPollOneMu
- Siblings
- 3
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ccRapPollOneMuInProcess Setting to true initiates the polling of one
specified MU's known AP table.
Once the switch receives a response from the
requested MU, it sets this value to false.
… | scalar | DoActionShowProgress | .1.3.6.1.4.1.388.11.2.7.4.2.2 |
| ccRapPollOneMuStatus Describes if the MU is associated or not, and if so,
if the MU is Symbol Rogue detect enabled or not. | scalar | Enumeration | .1.3.6.1.4.1.388.11.2.7.4.2.3 |
| ccRapPollOneMuResultsTable Shows the known AP table as read from the specified MU.
This table is NOT cumulative; that is, it only
reflects exactly what was read from the most recent
read of the … | table | - | .1.3.6.1.4.1.388.11.2.7.4.2.4 |