raidAdapterSubDeviceId
SUPERMICRO-SD5-MIB ·
.1.3.6.1.4.1.10876.100.1.9.1.12
Object
column
SNMPv2-TCDisplayString
The PCI sub-device id of the raid controller.
Context
- MIB
- SUPERMICRO-SD5-MIB
- OID
.1.3.6.1.4.1.10876.100.1.9.1.12- Type
- column
- Access
- readonly
- Status
- current
- Parent
- raidAdapterEntry
- Table
- raidAdapterTable
- Siblings
- 15
Values & Constraints
Type Constraints
range: 0..255
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| raidAdapterIndex Raid controller index. The unique value which identifies this raid controller. | column | Integer32 | .1.3.6.1.4.1.10876.100.1.9.1.1 |
| raidAdapterDeviceId The PCI device id of the raid controller. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10876.100.1.9.1.10 |
| raidAdapterSubVendorId The PCI sub-vendor id of the raid controller. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10876.100.1.9.1.11 |
| raidIsBBUAbsent Is the BBU absent or present?
Values: Absent, Present. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10876.100.1.9.1.13 |
| raidIsBBUAbsentIgnored Does the raid controller ignore the absent BBU?
Values: YES, NO.
If the value is No then the absent BBU will affect the all-in-one status of the raid controller. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10876.100.1.9.1.14 |
| raidAdapterAllinoneStatus Indicates the status of the raid controller. Values:
0: OK
1: Warning
2: Critical | column | Integer32 | .1.3.6.1.4.1.10876.100.1.9.1.15 |
| raidAdapterAllinoneMsg The status message of the raid controller. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10876.100.1.9.1.16 |
| raidAdapterGroup The group of the raid controller. Values:
LSI-MegaRAID
LSI-Fusion-MPT | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10876.100.1.9.1.2 |
| raidAdapterId The id of the raid controller. The id is unique in one adapter group. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10876.100.1.9.1.3 |
| raidAdapterProductName The product name of the raid controller. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10876.100.1.9.1.4 |
| raidAdapterSerialNumber The serial number of the raid controller. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10876.100.1.9.1.5 |
| raidAdapterFWPackageBuild The build number of the firmware package of the raid controller. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10876.100.1.9.1.6 |
| raidAdapterFWVersion The firmware version of the raid controller. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10876.100.1.9.1.7 |
| raidAdapterBIOSVersion The bios version of the raid controller. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10876.100.1.9.1.8 |
| raidAdapterVendorId The PCI vendor id of the raid controller. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.10876.100.1.9.1.9 |