sub10UnitMgmtSyncEMode

SUB10SYSTEMS-MIB · .1.3.6.1.4.1.39003.3.2.13.1

Object

scalar r/w Enumeration
The SyncE Mode. Setting this to syncEProvider(1) configures the unit as
a Slave clock. In this case the unit at the other end of the
link should be set to syncEConsumer(2).
          
IMPORTANT: This object is controlled by transaction management.
Any changes to this object must be transactionally acknowledged
following a successful set thus protecting against loss of
communication with the unit. To acknowledge the transaction
set the object sub10UnitMgmtTransaction to transactionCommit(2).

Context

MIB
SUB10SYSTEMS-MIB
OID
.1.3.6.1.4.1.39003.3.2.13.1
Type
scalar
Access
readwrite
Status
current
Parent
sub10UnitMgmtSyncE

Syntax

Enumeration

Values & Constraints

Enumerated Values
0syncENone
1syncEProvider
2syncEConsumer