spSensorIndex
SPAGENT-MIB ·
.1.3.6.1.4.1.3854.1.7.4
Object
scalar
mandatory
Integer32
The integer index of the sensor causing this trap to be sent
Context
- MIB
- SPAGENT-MIB
- OID
.1.3.6.1.4.1.3854.1.7.4- Type
- scalar
- Access
- readonly
- Status
- mandatory
- Parent
- sensorProbeTraps
- Siblings
- 22
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| spSensorStatus mandatory The current integer status of the sensor causing this trap to be sent | scalar | Enumeration | .1.3.6.1.4.1.3854.1.7.1 |
| spSensorSubIndex mandatory The integer sub index of the sensor causing this trap to be sent. Only for temperaturearray and relayarray | scalar | Integer32 | .1.3.6.1.4.1.3854.1.7.10 |
| spBoardIndex mandatory The integer index of the sensor board causing this trap to be sent. | scalar | Integer32 | .1.3.6.1.4.1.3854.1.7.11 |
| spBoardDescription mandatory The description of the sensor board causing this trap to be sent | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3854.1.7.12 |
| spEventTimeStamp mandatory The time(MM/DD/YYYY HH:MM:SS) of an event causing this trap to be sent | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3854.1.7.13 |
| spEventClassNumber mandatory The user-defined class number associated with this trap | scalar | Integer32 | .1.3.6.1.4.1.3854.1.7.14 |
| spEventClassName mandatory The user-defined class Name associated with this trap | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3854.1.7.15 |
| spSensorDecimalValue mandatory The current decimal value of the sensor causing this trap to be sent | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3854.1.7.16 |
| spSensorAliveHigh mandatory The highest sensor value in the period | scalar | Integer32 | .1.3.6.1.4.1.3854.1.7.17 |
| spSensorAliveLow mandatory The lowset sensor value in the period | scalar | Integer32 | .1.3.6.1.4.1.3854.1.7.18 |
| spSensorSensorId mandatory The sensor id of an event causing this trap to be sent | scalar | Integer32 | .1.3.6.1.4.1.3854.1.7.19 |
| spSensorValue mandatory The current integer value of the sensor causing this trap to be sent | scalar | Integer32 | .1.3.6.1.4.1.3854.1.7.2 |
| spSensorAccessCardId mandatory Access card id (this field will be 0 when it's not available) | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3854.1.7.20 |
| spSensorIndexSpp mandatory Sensor Index String | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3854.1.7.21 |
| spPreviousSensorStatus mandatory The previous integer status of the sensor causing this trap to be sent | scalar | Enumeration | .1.3.6.1.4.1.3854.1.7.22 |
| spPreviousSensorStatusName mandatory The previous status of the sensor causing this trap to be sent | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3854.1.7.23 |
| spSensorLevelExceeded mandatory The integer level that was exceeded causing this trap to be sent | scalar | Integer32 | .1.3.6.1.4.1.3854.1.7.3 |
| spSensorName mandatory The name of the sensor causing this trap to be sent | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3854.1.7.5 |
| spSensorDescription mandatory The description of the sensor causing this trap to be sent | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3854.1.7.6 |
| spSensorProbeKeepAlive mandatory Keep alive trap to be sent | scalar | Integer32 | .1.3.6.1.4.1.3854.1.7.7 |
| spSensorType mandatory Type of this sensor | scalar | Enumeration | .1.3.6.1.4.1.3854.1.7.8 |
| spSensorStatusName mandatory The current status of the sensor causing this trap to be sent | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3854.1.7.9 |