sensorProbeDrycontactArrayPort5GoOnline
SPAGENT-MIB ·
.1.3.6.1.4.1.3854.1.2.2.1.19.37.5.2.1.6
Object
column
mandatory
r/w
Enumeration
To put online enter a 1, to take offline enter a 2
Context
- MIB
- SPAGENT-MIB
- OID
.1.3.6.1.4.1.3854.1.2.2.1.19.37.5.2.1.6- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- sensorProbeDrycontactArrayPort5Entry
- Table
- sensorProbeDrycontactArrayPort5Table
- Siblings
- 15
Syntax
Enumeration
Values & Constraints
Object Constraints
range: 0-65534
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| sensorProbeDrycontactArrayPort5Index mandatory A unique value for each sensor DrycontactArray port. | column | Integer32 | .1.3.6.1.4.1.3854.1.2.2.1.19.37.5.2.1.1 |
| sensorProbeDrycontactArrayPort5ContTimeNormal mandatory Continuous time for this sensor to be in Normal before accepting new Status. | column | Integer32 | .1.3.6.1.4.1.3854.1.2.2.1.19.37.5.2.1.10 |
| sensorProbeDrycontactArrayPort5Description mandatory A Description of this sensor DrycontactArray | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3854.1.2.2.1.19.37.5.2.1.2 |
| sensorProbeDrycontactArrayPort5ManualOutputCycleTime mandatory Drycontact toggle period in seconds for Manual Cycle action. | column | Integer32 | .1.3.6.1.4.1.3854.1.2.2.1.19.37.5.2.1.24 |
| sensorProbeDrycontactArrayPort5ManualOutputAction mandatory Control the Drycontact output manualy | column | Enumeration | .1.3.6.1.4.1.3854.1.2.2.1.19.37.5.2.1.25 |
| sensorProbeDrycontactArrayPort5OutputDescOn mandatory Description of Drycontact output On | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3854.1.2.2.1.19.37.5.2.1.26 |
| sensorProbeDrycontactArrayPort5OutputDescOff mandatory Description of Drycontact output Off | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3854.1.2.2.1.19.37.5.2.1.27 |
| sensorProbeDrycontactArrayPort5URL mandatory Sensor URL link. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3854.1.2.2.1.19.37.5.2.1.28 |
| sensorProbeDrycontactArrayPort5OpenURL mandatory Open URL in this browser or open in a new window. | column | Enumeration | .1.3.6.1.4.1.3854.1.2.2.1.19.37.5.2.1.29 |
| sensorProbeDrycontactArrayPort5ControlMode mandatory Control Mode used for selecting the mode to control a Drycontact output. | column | Enumeration | .1.3.6.1.4.1.3854.1.2.2.1.19.37.5.2.1.30 |
| sensorProbeDrycontactArrayPort5Status mandatory The current status of this Sensor | column | Enumeration | .1.3.6.1.4.1.3854.1.2.2.1.19.37.5.2.1.4 |
| sensorProbeDrycontactArrayPort5Online mandatory If this Sensor is currently online | column | Enumeration | .1.3.6.1.4.1.3854.1.2.2.1.19.37.5.2.1.5 |
| sensorProbeDrycontactArrayPort5NormalState mandatory The normal state of DrycontactArray | column | Enumeration | .1.3.6.1.4.1.3854.1.2.2.1.19.37.5.2.1.7 |
| sensorProbeDrycontactArrayPort5Direction mandatory To set a drycontact to input enter 0. To set a switch to output enter 1 | column | Enumeration | .1.3.6.1.4.1.3854.1.2.2.1.19.37.5.2.1.8 |
| sensorProbeDrycontactArrayPort5ContTimeCritical mandatory Continuous time for this sensor to be in Critical before accepting new Status. | column | Integer32 | .1.3.6.1.4.1.3854.1.2.2.1.19.37.5.2.1.9 |