sensorDryContactStatus
SPAGENT-MIB ·
.1.3.6.1.4.1.3854.2.3.4.1.6
Object
column
mandatory
Enumeration
The current status of this Sensor, only input switches have a status
Context
- MIB
- SPAGENT-MIB
- OID
.1.3.6.1.4.1.3854.2.3.4.1.6- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- sensorDryContactEntry
- Table
- sensorDryContactTable
- Siblings
- 22
Syntax
Enumeration
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| sensorDryContactIndex mandatory The index into the Switch sensor table | column | Integer32 | .1.3.6.1.4.1.3854.2.3.4.1.1 |
| sensorDryContactId mandatory The Sensor ID of this sensor, used to identify which sensor it is in the system configuration. | column | Integer32 | .1.3.6.1.4.1.3854.2.3.4.1.1000 |
| sensorDryContactDescription mandatory A Description of this sensor Switch | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3854.2.3.4.1.2 |
| sensorDryContactDirection mandatory To set a switch to input enter 0. To set a switch to output enter 1 | column | Enumeration | .1.3.6.1.4.1.3854.2.3.4.1.22 |
| sensorDryContactNormalState mandatory The normal state of an input switch. If an input switch is in this state it is normal, else it is critical. An open switch senses +5 volts. A closed switch senses 0 volts. | column | Enumeration | .1.3.6.1.4.1.3854.2.3.4.1.23 |
| sensorDryContactControlMode mandatory Control Mode used for selecting the mode to control a sensor output. | column | Enumeration | .1.3.6.1.4.1.3854.2.3.4.1.24 |
| sensorDryContactOutputManualCycleTime mandatory Toggle period in seconds for Manual Cycle action. | column | Integer32 | .1.3.6.1.4.1.3854.2.3.4.1.25 |
| sensorDryContactOutputManualAction mandatory Control the sensor output manualy | column | Enumeration | .1.3.6.1.4.1.3854.2.3.4.1.26 |
| sensorDryContactType mandatory Enter the type of this Sensor | column | Enumeration | .1.3.6.1.4.1.3854.2.3.4.1.3 |
| sensorDryContactPort mandatory Sensor port | column | Integer32 | .1.3.6.1.4.1.3854.2.3.4.1.35 |
| sensorDryContactSubPort mandatory Sensor sub port | column | Integer32 | .1.3.6.1.4.1.3854.2.3.4.1.36 |
| sensorDryContactDeviceIndex mandatory Device Index of sensor | column | Integer32 | .1.3.6.1.4.1.3854.2.3.4.1.37 |
| sensorDryContactCriticalDesc mandatory A Critical Description of this sensor | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3854.2.3.4.1.46 |
| sensorDryContactNormalDesc mandatory A Normal Description of this sensor | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3854.2.3.4.1.48 |
| sensorDryContactOnDesc mandatory A On Description of this sensor | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3854.2.3.4.1.52 |
| sensorDryContactOffDesc mandatory A Off Description of this sensor | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3854.2.3.4.1.53 |
| sensorDryContactCriticalColor mandatory A Critical Color of this sensor | column | Integer32 | .1.3.6.1.4.1.3854.2.3.4.1.54 |
| sensorDryContactNormalColor mandatory A Normal Color of this sensor | column | Integer32 | .1.3.6.1.4.1.3854.2.3.4.1.56 |
| sensorDryContactOnColor mandatory A On Color of this sensor | column | Integer32 | .1.3.6.1.4.1.3854.2.3.4.1.60 |
| sensorDryContactOffColor mandatory A Off Color of this sensor | column | Integer32 | .1.3.6.1.4.1.3854.2.3.4.1.61 |
| sensorDryContactAcknowledge mandatory Dry Contact sensor acknowledge | column | Enumeration | .1.3.6.1.4.1.3854.2.3.4.1.70 |
| sensorDryContactGoOffline mandatory To take offline enter a 2 | column | Enumeration | .1.3.6.1.4.1.3854.2.3.4.1.8 |