relayControlMode
SPAGENT-MIB ·
.1.3.6.1.4.1.3854.3.5.12.1.24
Object
column
mandatory
r/w
Enumeration
The Control Mode for controlling this relay sensor with, it can be one of these: Manual, Notification, Time, Thermostat.
Context
- MIB
- SPAGENT-MIB
- OID
.1.3.6.1.4.1.3854.3.5.12.1.24- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- relayEntry
- Table
- relayTable
- Siblings
- 15
Syntax
Enumeration
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| relayIndex mandatory The Sensor Compound ID of this sensor, used to identify which sensor it is in the system configuration. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3854.3.5.12.1.1 |
| relayId mandatory The Sensor ID of this sensor, used to identify which sensor it is in the system configuration. | column | Integer32 | .1.3.6.1.4.1.3854.3.5.12.1.1000 |
| relayDescription mandatory The user specified description of this sensor. Unless specified, the default value is used. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3854.3.5.12.1.2 |
| relayManualCycleTime mandatory The time in seconds that the relay will stay in a state, before changing to the next state in case the cycle action have been used. | column | Integer32 | .1.3.6.1.4.1.3854.3.5.12.1.25 |
| relayManualAction mandatory The manual control for the relay state: Off, On, Toggle Off-On, Toggle On-Off. | column | Enumeration | .1.3.6.1.4.1.3854.3.5.12.1.26 |
| relayType mandatory The type of the sensor; it represents the sensor's functionality. For the relay sensor, it has 2 sub-type: normal relay, and xrelay. | column | Enumeration | .1.3.6.1.4.1.3854.3.5.12.1.3 |
| relayPort mandatory The device's sensor port number, where this sensor is plugged in to. | column | Integer32 | .1.3.6.1.4.1.3854.3.5.12.1.35 |
| relaySubPort mandatory The logical port number of this sensor on the array of a relay (xelay) sensor. For example x.1, x.2, x.3 ... | column | Integer32 | .1.3.6.1.4.1.3854.3.5.12.1.36 |
| relayOnDesc mandatory The user specified 'On' status description of this sensor. Unless specified, the default value is used. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3854.3.5.12.1.52 |
| relayOffDesc mandatory The user specified 'Off' Description of this sensor. Unless specified, the default value is used. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3854.3.5.12.1.53 |
| relayStatus mandatory The current status of this sensor. | column | Enumeration | .1.3.6.1.4.1.3854.3.5.12.1.6 |
| relayOnColor mandatory The user specified 'On' status field color. The unit will show this color on its web interface and in DCIM. Unless specified, the default value is used. | column | Integer32 | .1.3.6.1.4.1.3854.3.5.12.1.60 |
| relayOffColor mandatory The user specified 'Off' status field color. The unit will show this color on its web interface and in DCIM. Unless specified, the default value is used. | column | Integer32 | .1.3.6.1.4.1.3854.3.5.12.1.61 |
| relayAcknowledge mandatory The acknowledge status for the current status of the sensor: 0 = the status has been changed and waiting to be acknowledged, 1 = status is normal or have been already acknowledged… | column | Enumeration | .1.3.6.1.4.1.3854.3.5.12.1.70 |
| relayGoOffline mandatory Command to offline this sensor: use value '2' to set the sensor offline. | column | Enumeration | .1.3.6.1.4.1.3854.3.5.12.1.8 |