sonusSystemPowerSupplyStatusFanFault
SONUS-SYSTEM-MIB ·
.1.3.6.1.4.1.2879.2.8.5.1.8.1.19
Object
Indicates if there is fan fault.
Context
- MIB
- SONUS-SYSTEM-MIB
- OID
.1.3.6.1.4.1.2879.2.8.5.1.8.1.19- Type
- column
- Access
- readonly
- Status
- obsolete
- Parent
- sonusSystemPowerSupplyStatusEntry
- Table
- sonusSystemPowerSupplyStatusTable
- Siblings
- 19
Values & Constraints
Type Values
1 | true |
2 | false |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| sonusSystemPowerSupplyStatusServerName Identifies the server. | column | OctetString | .1.3.6.1.4.1.2879.2.8.5.1.8.1.1 |
| sonusSystemPowerSupplyStatusInputCurrent obsolete Indicates input current. | column | OctetString | .1.3.6.1.4.1.2879.2.8.5.1.8.1.10 |
| sonusSystemPowerSupplyStatusOutputPower obsolete Indicates output power in watts. | column | OctetString | .1.3.6.1.4.1.2879.2.8.5.1.8.1.11 |
| sonusSystemPowerSupplyStatusOutputVoltage obsolete Indicates output volatge. | column | OctetString | .1.3.6.1.4.1.2879.2.8.5.1.8.1.12 |
| sonusSystemPowerSupplyStatusOutputCurrent obsolete Indicates output current. | column | OctetString | .1.3.6.1.4.1.2879.2.8.5.1.8.1.13 |
| sonusSystemPowerSupplyStatusAmbientTemperature obsolete Indicates ambient temperature of the power supply unit. | column | OctetString | .1.3.6.1.4.1.2879.2.8.5.1.8.1.14 |
| sonusSystemPowerSupplyStatusFanSpeed obsolete Indicates the fan speed in RPM. | column | OctetString | .1.3.6.1.4.1.2879.2.8.5.1.8.1.15 |
| sonusSystemPowerSupplyStatusPowerFault Indicates if there is power fault. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.2879.2.8.5.1.8.1.16 |
| sonusSystemPowerSupplyStatusVoltageFault Indicates if there is voltage fault. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.2879.2.8.5.1.8.1.17 |
| sonusSystemPowerSupplyStatusCurrentFault obsolete Indicates if there is current fault. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.2879.2.8.5.1.8.1.18 |
| sonusSystemPowerSupplyStatusPowerSupplyId The name of the power supply (/SYS/VPS) | column | OctetString | .1.3.6.1.4.1.2879.2.8.5.1.8.1.2 |
| sonusSystemPowerSupplyStatusTemperatureFault obsolete Indicates if there is temperature fault. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.2879.2.8.5.1.8.1.20 |
| sonusSystemPowerSupplyStatusPresent Indicates if the module is present or not. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.2879.2.8.5.1.8.1.3 |
| sonusSystemPowerSupplyStatusProductName Identifies the name (as given by manufacturer) of power supply module. | column | OctetString | .1.3.6.1.4.1.2879.2.8.5.1.8.1.4 |
| sonusSystemPowerSupplyStatusSerialNum Identifies the serial number of the power supply module. This is the
serial number assigned to the server module at manufacture. | column | SonusNodeSrvrStatSerialNumType | .1.3.6.1.4.1.2879.2.8.5.1.8.1.5 |
| sonusSystemPowerSupplyStatusPartNum Identifies the part number of the module. This is the
part number assigned to the module at manufacture. | column | SonusNodeSrvrStatPartNumType | .1.3.6.1.4.1.2879.2.8.5.1.8.1.6 |
| sonusSystemPowerSupplyStatusManufactureDate obsolete The date this power supply module was manufactured. | column | SonusNodeSrvrStatMfgDateType | .1.3.6.1.4.1.2879.2.8.5.1.8.1.7 |
| sonusSystemPowerSupplyStatusInputPower obsolete Indicates input power in watts. | column | OctetString | .1.3.6.1.4.1.2879.2.8.5.1.8.1.8 |
| sonusSystemPowerSupplyStatusInputVoltage obsolete Indicates input volatge. | column | OctetString | .1.3.6.1.4.1.2879.2.8.5.1.8.1.9 |