vctAction

SNR-SWITCH-MIB · .1.3.6.1.4.1.40418.7.100.3.2.1.18

Object

column r/w Integer32
This object indicates the VCT action of the port, the value 1(standard mode) and value 2(shutdown mode) is permitted 
when SET this entry though you can GET 1(processing) and 0(succeed);
The specified port will be shutdown when one sets 1 to this entry by standard mode,and then it will return 
to no shutdown after operate the virtual-cable-test. You can get the status of VCT from the entry vctLastStatus.
			The specified port will be shutdown when one sets 2 to this entry by shutdown mode,and then it will return 
to operate the virtual-cable-test. You can get the status of VCT from the entry vctLastStatus.

Context

MIB
SNR-SWITCH-MIB
OID
.1.3.6.1.4.1.40418.7.100.3.2.1.18
Type
column
Access
readwrite
Status
current
Parent
priPortEntry

Syntax

Integer32

Values & Constraints

No enumerated values or constraints recorded.