sdlcLSAdminRNRLIMIT
SNA-SDLC-MIB ·
.1.3.6.1.2.1.41.1.2.1.1.14
Object
This object controls the length of time (in
1/100ths of a second) that an SDLC link station
will allow its adjacent link station to remain
in a busy (RNR) state before declaring it
inoperative.
A value of sdlcLSAdminRNRLIMIT == 0 means there
is no limit.
The object descriptor contains the name of an
NCP configuration parameter, RNRLIMIT. Please
note that the value of this object represents
1/100ths of a second while the NCP RNRLIMIT is
represented in minutes.
Depending on the implementation, a write
operation to this administered value may not
change the operational value,
sdlcLSOperRNRLIMIT, until the link station is
cycled inactive.
Context
- MIB
- SNA-SDLC-MIB
- OID
.1.3.6.1.2.1.41.1.2.1.1.14- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- sdlcLSAdminEntry
Syntax
SNMPv2-TCTimeInterval
Values & Constraints
No enumerated values or constraints recorded.