sleAlarmControlVariable

SLE-RMON-MIB · .1.3.6.1.4.1.6296.101.9.2.2.8

Object

scalar r/w ObjectIdentifier
The object identifier of the particular variable to
be sampled.  Only variables that resolve to an ASN.1
primitive type of INTEGER (INTEGER, Counter, Gauge,
or TimeTicks) may be sampled.
          
Because SNMP access control is articulated entirely
in terms of the contents of MIB views, no access
control mechanism exists that can restrict the value
of this object to identify only those objects that
exist in a particular MIB view.  Because there is
thus no acceptable means of restricting the read
access that could be obtained through the alarm
mechanism, the probe must only grant write access to
this object in those views that have read access to
all objects on the probe.
          
During a set operation, if the supplied variable
name is not available in the selected MIB view, a
badValue error must be returned.  If at any time the
variable name of an establisled alarmEntry is no
longer available in the selected MIB view, the probe
must change the status of this alarmEntry to
invalid(4).
          
This object may not be modified if the associated
alarmStatus object is equal to valid(1).

Context

MIB
SLE-RMON-MIB
OID
.1.3.6.1.4.1.6296.101.9.2.2.8
Type
scalar
Access
readwrite
Status
current
Parent
sleAlarmControl
Siblings
15

Syntax

ObjectIdentifier

Values & Constraints

No enumerated values or constraints recorded.

Related Objects

Sibling Objects