esOutputCombinedStatusBlock2
SITEBOSS-530-STD-MIB ·
.1.3.6.1.4.1.3052.12.2.1.2.1.35
Object
column
SNMPv2-TCDisplayString
Combined status string intended to be parsed by NMS: numInBlock`namex`valuex`aliasx~namey`valuey`aliasy~...namez`valuez`aliasz
Context
- MIB
- SITEBOSS-530-STD-MIB
- OID
.1.3.6.1.4.1.3052.12.2.1.2.1.35- Type
- column
- Access
- readonly
- Status
- current
- Parent
- esEntry
- Table
- esTable
- Siblings
- 34
Values & Constraints
Type Constraints
range: 0..255
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| esIndex This number refers to an EventSensor; it has the
same meaning as the esIndexES object (see above),
except that this object is used only within the
esTable branch.
T… | column | Integer32 | .1.3.6.1.4.1.3052.12.2.1.2.1.1 |
| esNumberNoiseSensors The number of noise sensors on the EventSensor. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3052.12.2.1.2.1.10 |
| esNoiseReportingMode Description of how noise sensor values should be
interpreted. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.12.2.1.2.1.11 |
| esNumberAirflowSensors The number of airflow sensors on the EventSensor. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3052.12.2.1.2.1.12 |
| esAirflowReportingMode Description of how airflow sensor values should be
interpreted. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.12.2.1.2.1.13 |
| esNumberAnalog The number of analog inputs on the EventSensor. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3052.12.2.1.2.1.14 |
| esAnalogReportingMode Description of how analog input values should be
interpreted. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.12.2.1.2.1.15 |
| esNumberOutputs The number of outputs (relay or power) on the EventSensor | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3052.12.2.1.2.1.16 |
| esOutputReportingMode Description of how output values should be interpreted. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.12.2.1.2.1.17 |
| esTempCombinedStatus Combined status string intended to be parsed by NMS:
name`value`scale`eventState`eventColorCode | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.12.2.1.2.1.18 |
| esCCCombinedStatusBlock1 Combined status string intended to be parsed by NMS:
numInBlock~name1`value1`eventColorCode1`alias1~name2`value2`eventColorCode2`alias2~...name8`value8`eventColorCode8`alias8 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.12.2.1.2.1.19 |
| esName The name of the EventSensor | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.12.2.1.2.1.2 |
| esCCCombinedStatusBlock2 Combined status string intended to be parsed by NMS:
numInBlock~name9`value9`eventColorCode9`alias9~name10`value10`eventColorCode10`alias10~...name16`value16`eventColorCode16`alia… | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.12.2.1.2.1.20 |
| esCCCombinedStatusBlock3 Combined status string intended to be parsed by NMS:
numInBlock~name17`value17`eventColorCode17`alias17~name18`value18`eventColorCode18`alias18~...name24`value24`eventColorCode24`… | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.12.2.1.2.1.21 |
| esCCCombinedStatusBlock4 Combined status string intended to be parsed by NMS:
numInBlock~name25`value25`eventColorCode25`alias25~name26`value26`eventColorCode26`alias26~...name32`value32`eventColorCode32`… | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.12.2.1.2.1.22 |
| esCCCombinedStatusBlock5 Combined status string intended to be parsed by NMS:
numInBlock~name33`value33`eventColorCode33`alias33~name34`value34`eventColorCode34`alias35~...name40`value40`eventColorCode40`… | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.12.2.1.2.1.23 |
| esCCCombinedStatusBlock6 Combined status string intended to be parsed by NMS:
numInBlock~name41`value41`eventColorCode41`alias41~name42`value42`eventColorCode42`alias43~...name48`value48`eventColorCode48`… | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.12.2.1.2.1.24 |
| esCCCombinedStatusBlock7 Combined status string intended to be parsed by NMS:
numInBlock~name49`value49`eventColorCode49`alias49~name50`value50`eventColorCode50`alias50~...name56`value56`eventColorCode56`… | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.12.2.1.2.1.25 |
| esCCCombinedStatusBlock8 Combined status string intended to be parsed by NMS:
numInBlock~name57`value57`eventColorCode57`alias57~name57`value57`eventColorCode564`alias57~...name64`value64`eventColorCode64… | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.12.2.1.2.1.26 |
| esHumidCombinedStatus Combined status string intended to be parsed by NMS:
name`value`eventState`eventColorCode | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.12.2.1.2.1.27 |
| esAnalogCombinedStatusBlock1 Combined status string intended to be parsed by NMS:
numInBlock~name1`value1`units1`eventState`eventColorCode1~name2`value2`units2`eventState`eventColorCode2~... | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.12.2.1.2.1.28 |
| esAnalogCombinedStatusBlock2 Combined status string intended to be parsed by NMS:
numInBlock~name9`value9`units9`eventState9`eventColorCode9~... | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.12.2.1.2.1.29 |
| esID The factory-assigned ID of the EventSensor | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.12.2.1.2.1.3 |
| esAnalogCombinedStatusBlock3 Combined status string intended to be parsed by NMS:
numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~... | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.12.2.1.2.1.30 |
| esAnalogCombinedStatusBlock4 Combined status string intended to be parsed by NMS:
numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~... | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.12.2.1.2.1.31 |
| esAnalogCombinedStatusBlock5 Combined status string intended to be parsed by NMS:
numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~... | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.12.2.1.2.1.32 |
| esAnalogCombinedStatusBlock6 Combined status string intended to be parsed by NMS:
numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~... | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.12.2.1.2.1.33 |
| esOutputCombinedStatusBlock1 Combined status string intended to be parsed by NMS:
numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~... | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.12.2.1.2.1.34 |
| esNumberTempSensors The number of temperature sensors on the EventSensor | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3052.12.2.1.2.1.4 |
| esTempReportingMode Description of how temperature values should
be interpreted. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.12.2.1.2.1.5 |
| esNumberCCs The number of contact closures on the EventSensor. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3052.12.2.1.2.1.6 |
| esCCReportingMode Description of how CC values should be interpreted. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.12.2.1.2.1.7 |
| esNumberHumidSensors The number of humidity sensors on the EventSensor. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3052.12.2.1.2.1.8 |
| esHumidReportingMode Description of how humidity sensor values should be
interpreted. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.12.2.1.2.1.9 |