bmChargingCurrentVHighActions
SITEBOSS-450-STD-MIB ·
.1.3.6.1.4.1.3052.17.2.12.14.7.1.5
Object
Actions for very high charging current event.
Context
- MIB
- SITEBOSS-450-STD-MIB
- OID
.1.3.6.1.4.1.3052.17.2.12.14.7.1.5- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- bmChargingCurrentEntry
- Table
- batteryMonitorChargingCurrentTable
- Siblings
- 16
Values & Constraints
Type Constraints
range: 0..255
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| bmChargingCurrentIndex Which battery monitor in the battery monitor charging current config table. | column | Integer32 | .1.3.6.1.4.1.3052.17.2.12.14.7.1.1 |
| bmChargingCurrentHighTrapNum Trap number for high charging current event. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3052.17.2.12.14.7.1.10 |
| bmChargingCurrentHighClass Class for high charging current event. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.17.2.12.14.7.1.11 |
| bmChargingCurrentNormalActions Actions for return to normal charging current event. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.17.2.12.14.7.1.12 |
| bmChargingCurrentNormalTrapNum Trap number for return to normal charging current event. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3052.17.2.12.14.7.1.13 |
| bmChargingCurrentNormalClass Class for return to normal charging current event. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.17.2.12.14.7.1.14 |
| bmChargingCurrentSysrepEnable System reporting enable for charging current telemetry. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.17.2.12.14.7.1.15 |
| bmChargingCurrentSysrepThreshold System reporting threshold for charging current telemetry. This is a
floating point value. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.17.2.12.14.7.1.16 |
| bmChargingCurrentSysrepLimit System reporting limit for charging current telemetry. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3052.17.2.12.14.7.1.17 |
| bmChargingCurrentEnable Enable/disable charging current event. This event is based on
positive current flow (i.e. current flowing into the battery string). | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.17.2.12.14.7.1.2 |
| bmChargingCurrentDeadband Deadband in amperes. This is a floating point value. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.17.2.12.14.7.1.3 |
| bmChargingCurrentVHighValue Very high event threshold, in volts. This is a floating point value. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.17.2.12.14.7.1.4 |
| bmChargingCurrentVHighTrapNum Trap number for very high charging current event. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3052.17.2.12.14.7.1.6 |
| bmChargingCurrentVHighClass Class for very high charging current event. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.17.2.12.14.7.1.7 |
| bmChargingCurrentHighValue High event threshold, in volts. This is a floating point value. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.17.2.12.14.7.1.8 |
| bmChargingCurrentHighActions Actions for high charging current event. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.3052.17.2.12.14.7.1.9 |