es1DcSys1ConfigList
SITE-MONITORING-MIB ·
.1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3
Object
node
No description available.
Context
- MIB
- SITE-MONITORING-MIB
- OID
.1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3- Type
- node
- Parent
- es1DcSys1Config
- Siblings
- 2
- Children
- 64
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| es1DcSys1ConfigNumber The number of entries in the Config table related to the DC System | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.1 |
| es1DcSys1ConfigTable The table of Config entries related to the DC System | table | - | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.2 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| es1DcSys1CfgBatMeasurementSourceVoltage NA | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.100 |
| es1DcSys1CfgBatMeasurementSourceCurrent NA | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.101 |
| es1DcSys1CfgBatCharacteristicsType The chemistry of the installed battery. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.102 |
| es1DcSys1CfgBatCharacteristicsNumberOfCells Number of cells in each string. This is also valid if there is only one string | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.103 |
| es1DcSys1CfgBatCharacteristicsStringCapacity The capacity of each string in Ah | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.104 |
| es1DcSys1CfgBatCharacteristicsNumberOfString Number of string | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.105 |
| es1DcSys1CfgBatAutonomyPeukertNumber The Peukert number relates to the internal resistance of a battery and provides an indication of the expected capacity. The ideal number is 1. This value can be calculated with th… | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.106 |
| es1DcSys1CfgBatAutonomyMaxDepthOfDischargeforEstimation It is generally recommended to discharge maximum 60% of the battery capacity to enhance battery lifetime. By default, 100% is used for autonomy calculation. This parameter can als… | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.107 |
| es1DcSys1CfgBatFloatVoltagePerCell Value is in Volts with 2 decimals. This value should be found in battery's data sheet. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.111 |
| es1DcSys1CfgBatFloatSource NA | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.112 |
| es1DcSys1CfgBatCurrentLimitationEnabled This allows to enable or disable the charging current limitation. It is highly recommended to leave this parameter by default (enabled) in order to avoid severe damages. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.113 |
| es1DcSys1CfgBatCurrentLimitationCurrentLimit The max charging current can be computed using the installed capacity times the wished C rate. For the specific case of NiZn battery, the recommended standard charging current lim… | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.114 |
| es1DcSys1CfgBatCurrentLimitationSource NA | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.115 |
| es1DcSys1CfgBatTempAlarmLowThreshold The temperature under which the alarm 'Battery Temperature Too Low' must be set. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.121 |
| es1DcSys1CfgBatTempAlarmHighThreshold The temperature over which the alarm 'Battery Temperature Too High' must be set. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.122 |
| es1DcSys1CfgBatTempAlarmHighHysteresis NA | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.123 |
| es1DcSys1CfgBatTempDisableChargeWhenTooHigh Disable the charge when related alarm is set | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.126 |
| es1DcSys1CfgBatTempCompensationEnabled Temperature compensation configuration | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.151 |
| es1DcSys1CfgBatTempCompensationCellCoefficient Coefficient for temperature compensation per cell (in mV/degreeCelsius/cell) | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.152 |
| es1DcSys1CfgBatTempCompensationReferenceTemp Reference temperature for temperature compensation (in degree Celsius) | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.153 |
| es1DcSys1CfgBatTempCompensationMinTemp Below this temperature (in degree Celsius), the voltage corresponding to this threshold is applied continuously | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.154 |
| es1DcSys1CfgBatTempCompensationMaxTemp Above this temperature (in degree Celsius), the voltage corresponding to this threshold is applied continuously | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.155 |
| es1DcSys1CfgBatBoostEnabled Tick to enable boost charging | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.201 |
| es1DcSys1CfgBatBoostVoltagePerCell Boost charging voltage per cell (0,01V precision) | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.202 |
| es1DcSys1CfgBatBoostTimeoutEnabled Tick to enable an automatic stop after the configured delay | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.203 |
| es1DcSys1CfgBatBoostTimeoutDuration Delay before an automatic stop (in seconds) | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.204 |
| es1DcSys1CfgBatBoostStopOnLowCurrentEnabled Tick to enable an automatic stop if the current goes below the configured threshold | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.205 |
| es1DcSys1CfgBatBoostStopOnLowCurrentThreshold Low current threshold for automatic stop (0,1A precision)) | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.206 |
| es1DcSys1CfgBatBoostStartOnLowCellVoltageEnabled Tick to enable a boost if cell voltage drops below the configured threshold voltage | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.207 |
| es1DcSys1CfgBatBoostStartOnLowCellVoltageThreshold Low cell voltage start threshold (0,01V precision) | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.208 |
| es1DcSys1CfgBatBoostStopOnTempHighEnabled Tick to enable an automatic stop of the boost if the battery temperature exceeds the specified threshold | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.209 |
| es1DcSys1CfgBatBoostStartOnLongDischargeEnabled Tick to enable a boost if the discharge exceeds the configured duration | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.211 |
| es1DcSys1CfgBatBoostStartOnLongDischargeThreshold Minimal discharge duration for an automated boost (in seconds) | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.212 |
| es1DcSys1CfgBatTestEnabled Tick to enable battery testing | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.251 |
| es1DcSys1CfgBatTestType In DC + AC type, the system will discharge the battery at the configured constant power using AC and DC.
In DC only mode, the converter will set its DC output voltage to the confi… | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.252 |
| es1DcSys1CfgBatTestPowerSetpoint If AC input reinjection is disabled, test power set point should be lower than AC output power. Set point is in Watts | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.253 |
| es1DcSys1CfgBatTestTimeoutDuration Duration timeout value | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.254 |
| es1DcSys1CfgBatTestLowStop Low voltage stop threshold per cell (0,01V precision) | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.255 |
| es1DcSys1CfgBatTestScheduling Scheduling enabled | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.261 |
| es1DcSys1CfgBatTestSchedulerCronRule NA | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.262 |
| es1DcSys1CfgBatTestGuardTime This parameter lets the user enable a minimum amount of time between two tests or between a discharge and a test | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.271 |
| es1DcSys1CfgBatTestGuardTimeduration Guard time duration in hours | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.272 |
| es1DcSys1CfgBatTestEnableACLossGuard When enabled, automated test will fail if the last ac loss occured to close to the test. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.273 |
| es1DcSys1CfgBatTestAcLossGuardValue Minimal time (in hours) between a loss of ac and the start of an automated test. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.274 |
| es1DcSys1CfgBatDisconnectGlobalPresence Low Voltage Disconnect settings | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.301 |
| es1DcSys1CfgBatDisconnectGlobalInhibit This setting allows the user to inhibit LVD operation and therefore to maintain LVD closed. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.302 |
| es1DcSys1CfgBatDisconnectVoltageTooLowEnabled Low Voltage Disconnect settings | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.310 |
| es1DcSys1CfgBatDisconnectVoltageTooLowThreshold Threshold voltage for opening (0,1V precision) | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.311 |
| es1DcSys1CfgBatDisconnectGlobalClosingDelay Delay before LVD closing | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.312 |
| es1DcSys1CfgBatDisconnectGlobalOpeningDelay Shutdown sequence duration (in seconds) | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.313 |
| es1DcSys1CfgBatDisconnectTempTooHighEnabled NA | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.321 |
| es1DcSys1CfgBatDisconnectTempTooHighDisconnectThreshold NA | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.322 |
| es1DcSys1CfgBatDisconnectTempTooHighReconnectThreshold NA | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.323 |
| es1DcSys1CfgBatStringsMidpointUnbalanceAlarmThreshold NA | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.350 |
| es1DcSys1CfgBatStringsMidpointUnbalanceAlarmHysteresis NA | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.351 |
| es1DcSys1CfgLoadNumberofLoads Number of independent load | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.401 |
| es1DcSys1CfgDCBusVoltageAlarmLowThreshold The bus voltage under which the alarm 'DC Bus Voltage Low' is set. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.50 |
| es1DcSys1CfgDCBusVoltageAlarmLowClearThreshold The bus voltage over which the alarm 'DC Bus Voltage Low' is unset. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.51 |
| es1DcSys1CfgDCBusVoltageAlarmHighThreshold The bus voltage under which the alarm 'DC Bus Voltage Low' is set. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.52 |
| es1DcSys1CfgDCBusVoltageAlarmHighClearThreshold The bus voltage over which the alarm 'DC Bus Voltage Low' is unset. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.53 |
| es1DcSys1CfgGenericEventsEventTableLength The maximum length of the table. The value must be comprised between 10 and 4000 | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.601 |
| es1DcSys1CfgBatGlobalPresence NA | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.90 |
| es1DcSys1CfgPLCGlobalNumberOfCustomData The number of PLC data. Every equipment can manage up to 30 user programmable data. Data elements are automatically added in the data table. Configuration parameters are added to … | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.901 |
| es1DcSys1CfgPLCGlobalNumberOfCustomAlarm The number of PLC alarm. Every equipment can manage up to 30 user programmable alarms. Alarm elements are automatically added in the alarm table. The alarm parameters are added to… | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.12551.20.1.20.1.20.1.15.3.902 |