alarmAntiFlooding

SIAE-ALARM-MIB · .1.3.6.1.4.1.3373.1103.4.28

Object

scalar r/w Enumeration
Enables or disables the alarm anti-flooding (filtering)
algorithm. According to such algorithm if the number of
event notifications that an alarm receives within a
specified time period, namely the observation period, exceeds
a given high threshold value, the alarm enters a 'flooding'
state. Once an alarm has entered such flooding state,
its status is forced to active, according to its related
severity, and no further event notifications are processed
(neither trapped nor logged).
An alarm exits the flooding state when the number of event
notifications, received within a subsequent observation
period, drops below a given low thresold value. On exiting
the flooding state, the trap and log status of an alarm get
aligned to the last notified event.

Context

MIB
SIAE-ALARM-MIB
OID
.1.3.6.1.4.1.3373.1103.4.28
Type
scalar
Access
readwrite
Status
current
Parent
smalarm
Siblings
30

Syntax

Enumeration

Values & Constraints

Enumerated Values
1disable
2enable

Related Objects

Sibling Objects