acmsTpProfile15mThreshold
SIAE-ACM-STATISTICS-MIB ·
.1.3.6.1.4.1.3373.1103.75.3.1.4
Object
Number of seconds within a 15 minutes interval to set
acmsTpProfile15mAlarm. The special value 0 turn off the alarm.
For downshift and upshift profiles, this threshold reports
the number of times a profile must be changed within a 15 minutes
interval to set acmsTpProfile15mAlarm.
Context
- MIB
- SIAE-ACM-STATISTICS-MIB
- OID
.1.3.6.1.4.1.3373.1103.75.3.1.4- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- acmsTpProfileRecord
- Table
- acmsTpProfileTable
- Siblings
- 5
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| acmsTpProfileId This object identifies the ACM profile of the radio system. | column | AcmProfile | .1.3.6.1.4.1.3373.1103.75.3.1.1 |
| acmsTpProfile15mAlarm If acmsCounteValue crosses the threshold acmsTpProfile15mThreshold,
this alarm is notified. | column | SIAE-ALARM-MIBAlarmStatus | .1.3.6.1.4.1.3373.1103.75.3.1.2 |
| acmsTpProfile24hAlarm If acmsCounteValue crosses the threshold acmsTpProfile24hThreshold,
this alarm is notified. | column | SIAE-ALARM-MIBAlarmStatus | .1.3.6.1.4.1.3373.1103.75.3.1.3 |
| acmsTpProfile24hThreshold Number of seconds within a 24 hours interval to set
acmsTpProfile24hAlarm. The special value 0 turn off the alarm.
For the profiles downshift and upshift, this thr… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.3373.1103.75.3.1.5 |
| acmsTpProfileRowStatus Status of this row of acmsTpProfileTable.
A row in the acmsTpProfileTable may not be created,
deleted, set to notInService or otherwise modified
if the there is no … | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.3373.1103.75.3.1.6 |