rsTTPEntry
SDH-ETS-MIB ·
.1.3.6.1.4.1.1038.110.20.2.1
Object
row
A particular regenerator section terminaison of the equipment.
Context
- MIB
- SDH-ETS-MIB
- OID
.1.3.6.1.4.1.1038.110.20.2.1- Type
- row
- Status
- current
- Parent
- rsTTPTable
- Table
- rsTTPTable
- Children
- 12
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| rsTTPIndex A unique value which identify a particular
synchronous physical interface.
The value of this index is always the same as spiTTPIndex. | column | Integer32 | .1.3.6.1.4.1.1038.110.20.2.1.1 |
| rsTTPF1SrcPointer A reference to the object which sends the data flow to
F1 RSOH byte.Zero indicates not used | column | Integer32 | .1.3.6.1.4.1.1038.110.20.2.1.10 |
| rsTTPSesThreshold The number of errors above which the second is declared
severely errored for this interface/function.
This value apply for near and far interface/function | column | Integer32 | .1.3.6.1.4.1.1038.110.20.2.1.11 |
| rsTTPEOWByteLine The line determines the SOH byte selected for Engineering
Order Wire: SOH starts with 3 lines of RSOH (1,2,3) and
finish with 5 lines of MSOH (5,6,7,8,9)
E1 is on line 2 colum… | column | Integer32 | .1.3.6.1.4.1.1038.110.20.2.1.12 |
| rsTTPEOWByteColumn The column determines the SOH byte selected for Engineering
Order Wire: SOH is composed of Col [1,9]
E1 is on line 2 column 4.
Zero indicates EOW not used, value different fr… | column | Integer32 | .1.3.6.1.4.1.1038.110.20.2.1.13 |
| rsTTPMonitor When the value of this field is set to false, the failure detection
is stopped for this regenerator section terminaison. | column | EQUIPMENT-MIBSagemBoolean | .1.3.6.1.4.1.1038.110.20.2.1.2 |
| rsTTPLof Severity associed with Loss Of Frame failure
for regenerator section terminaison. | column | EQUIPMENT-MIBSeverity | .1.3.6.1.4.1.1038.110.20.2.1.20 |
| rsTTPName A text string which identifies the particular entry among the
regenerator section terminaison entries. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1038.110.20.2.1.3 |
| rsTTPFailure Active failures on regenerator section terminaison | column | RsTTPFailure | .1.3.6.1.4.1.1038.110.20.2.1.4 |
| rsTTPSeverity Severity associed active Failure for regenerator section terminaison. | column | EQUIPMENT-MIBSeverity | .1.3.6.1.4.1.1038.110.20.2.1.5 |
| rsTTPEOWMode Mode used for EOW: Codir or contradir Master | column | EOWMode | .1.3.6.1.4.1.1038.110.20.2.1.8 |
| rsTTPE1SrcPointer A reference to the object which sends the data flow to
E1 RSOH byte (index in X21 table)
Usualy E1 carries X21 EOW (engineering order wire) data
and thus the pointer s value refer… | column | Integer32 | .1.3.6.1.4.1.1038.110.20.2.1.9 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| rsTTPIndex A unique value which identify a particular
synchronous physical interface.
The value of this index is always the same as spiTTPIndex. | column | Integer32 | .1.3.6.1.4.1.1038.110.20.2.1.1 |