msTTPProtectionType
SDH-ETS-MIB ·
.1.3.6.1.4.1.1038.110.30.2.1.2
Object
column
r/w
ProtectionType
The value of this field indicates the kind of wanted multiplex section protection. The default value is NONE. if value is changed in msp(1) or msSPRing(2) then (if it's possible) an entry is created respectivelly in mspTable or msSPRingTable. But these tables have to be completed to obtain a configured protection. If value is changed in None(0)then the associated entry in mspTable or msSPRingTable is deleted (if it's possible).
Context
- MIB
- SDH-ETS-MIB
- OID
.1.3.6.1.4.1.1038.110.30.2.1.2- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- msTTPEntry
- Table
- msTTPTable
- Siblings
- 15
Syntax
ProtectionType
- Source
- ProtectionType
- Base type
Enumeration
Values & Constraints
Type Values
0 | none |
1 | msp |
2 | msSPRing |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| msTTPIndex A unique value which identify a particular
synchronous physical interface.
The value of this index is always the same as spiTTPIndex | column | Integer32 | .1.3.6.1.4.1.1038.110.30.2.1.1 |
| msTTPEOWByteColumn The column determines the SOH byte selected for Engineering
Order Wire: SOH is composed of Col [1,9]
E2 is on line 9 column 7.
Zero indicates EOW not used, value diff… | column | Integer32 | .1.3.6.1.4.1.1038.110.30.2.1.10 |
| msTTPMonEber If the value of this field is true, the eber is monitored and is used as
MSP and SETS criterium.
If this defect is detected, an ais signal is send downstream and
rdi upstream. | column | EQUIPMENT-MIBSagemBoolean | .1.3.6.1.4.1.1038.110.30.2.1.11 |
| msTTPSdThreshold A Signal Degrade failure is declared if the error block rate is
greater than 1E(-mstSdThreshold).
The Signal Degrade failure desapeared when the error block rate is
less than 1E(1… | column | Integer32 | .1.3.6.1.4.1.1038.110.30.2.1.12 |
| msTTPSesThreshold The number of errors above which the second is declared
severely errored for this interface/function.
This value apply for near and far interface/function | column | Integer32 | .1.3.6.1.4.1.1038.110.30.2.1.13 |
| msTTPEber Severity associed with Excecive Bit Error Rate failure
for multiplex section terminaison. | column | EQUIPMENT-MIBSeverity | .1.3.6.1.4.1.1038.110.30.2.1.20 |
| msTTPSd Severity associed with Signal Degrade failure
for multiplex section terminaison. | column | EQUIPMENT-MIBSeverity | .1.3.6.1.4.1.1038.110.30.2.1.21 |
| msTTPRdi Severity associed with Remote Defect Indication failure
for multiplex section terminaison. | column | EQUIPMENT-MIBSeverity | .1.3.6.1.4.1.1038.110.30.2.1.22 |
| msTTPMonitor When the value of this field is set to false, the failure detection
is stopped for this multiplex section terminaison. | column | EQUIPMENT-MIBSagemBoolean | .1.3.6.1.4.1.1038.110.30.2.1.3 |
| msTTPName A text string which identifies the particular entry among the
multiplex section terminaison entries. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1038.110.30.2.1.4 |
| msTTPFailure Active failures on multiplex section terminaison | column | MsTTPFailure | .1.3.6.1.4.1.1038.110.30.2.1.5 |
| msTTPSeverity Severity associed with active failures on multiplex section terminaison. | column | EQUIPMENT-MIBSeverity | .1.3.6.1.4.1.1038.110.30.2.1.6 |
| msTTPEOWMode Mode used for EOW: Codir or contradir Master | column | EOWMode | .1.3.6.1.4.1.1038.110.30.2.1.7 |
| msTTPE2SrcPointer A reference to the object which sends the data flow to
E2 MSOH byte.
Usualy E2 carries X21 EOW (engineering order wire) data.
The reference is an index in X21 table.Zero indicates… | column | Integer32 | .1.3.6.1.4.1.1038.110.30.2.1.8 |
| msTTPEOWByteLine The line determines the SOH byte selected for Engineering
Order Wire: SOH starts with 3 lines of RSOH (1,2,3) and
finish with 5 lines of MSOH (5,6,7,8,9)
E2 is on lin… | column | Integer32 | .1.3.6.1.4.1.1038.110.30.2.1.9 |