heOpAmpUnitOutputStatus
SCTE-HMS-HE-OPTICAL-AMPLIFIER-MIB ·
.1.3.6.1.4.1.5591.1.11.1.3.1.1.1.1.1
Object
column
SCTE-HMS-HEADENDIDENT-MIBHeOnOffStatus
The output status of the amplifier.
If all the outputs of the amplifier are off then
the variable value shall be off(1), else the value
shall be on(2).
This object must provide for the alarm management capabilities
with a corresponding entry in the discretePropertyTable of
SCTE-HMS-PROPERTY-MIB (HMS026).
An alarm shall be recorded as an entry in the currentAlarmTable
of SCTE-HMS-PROPERTY-MIB (HMS026).
A log record shall be added as an entry in the heCommonLogTable.
An heCommonAlarmEvent notification shall be sent.
Context
- MIB
- SCTE-HMS-HE-OPTICAL-AMPLIFIER-MIB
- OID
.1.3.6.1.4.1.5591.1.11.1.3.1.1.1.1.1- Type
- column
- Access
- readonly
- Status
- current
- Parent
- heOpAmpUnitEntry
- Table
- heOpAmpUnitTable
- Siblings
- 1
Syntax
SCTE-HMS-HEADENDIDENT-MIBHeOnOffStatus
- Source
- SCTE-HMS-HEADENDIDENT-MIBHeOnOffStatus
- Base type
Enumeration
Values & Constraints
Type Values
1 | off |
2 | on |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| heOpAmpUnitOnOffControl This variable controls the output status of the amplifer.
Setting this variable to off(1) will cause all the
amplifier outputs to be shut off.
Set… | column | SCTE-HMS-HEADENDIDENT-MIBHeOnOffControl | .1.3.6.1.4.1.5591.1.11.1.3.1.1.1.1.2 |