deviceConfigEntry
SCHLEIFENBAUER-GENERIC-MIB ·
.1.3.6.1.4.1.44568.1.1.3.1.1
Object
row
A list to display device configuration.
Context
- MIB
- SCHLEIFENBAUER-GENERIC-MIB
- OID
.1.3.6.1.4.1.44568.1.1.3.1.1- Type
- row
- Status
- current
- Parent
- deviceConfigTable
- Table
- deviceConfigTable
- Children
- 13
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| configDeviceIndex A unique value for each PDU. Its value
ranges between 1 and the value of pduCount. | column | Integer32 | .1.3.6.1.4.1.44568.1.1.3.1.1.1 |
| configNrPhases Total number of inputs: either zero (for no input metering), one or three for a single or three phase system. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44568.1.1.3.1.1.10 |
| configNrOutlSwitched Total number of switched outlets available. If the numbering of outlets used is non-contiguous: the highest outlet number is assumed as amount of switched outlets. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44568.1.1.3.1.1.11 |
| configNoTotals The number of total calculations available in the PDU, this is usually one but can be more. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44568.1.1.3.1.1.12 |
| configVoltRating Voltage rating in V for this PDU. | column | OctetString | .1.3.6.1.4.1.44568.1.1.3.1.1.13 |
| configMaximumLoad Maximum rated load of the device per phase (this value is also mentioned on the PDU profile), usually either 16A, 32A or 63A. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44568.1.1.3.1.1.2 |
| configCustomerName Custom 64 character name field for the customer. | column | OctetString | .1.3.6.1.4.1.44568.1.1.3.1.1.3 |
| configFormFactor Formfactor of the device. | column | OctetString | .1.3.6.1.4.1.44568.1.1.3.1.1.4 |
| configLength Length of the device in millimeter. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44568.1.1.3.1.1.5 |
| configNoBranches The number of branches available in the PDU, can be zero if no branches are available in the configuration. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44568.1.1.3.1.1.6 |
| configNrOutlMeasured Number of measured outlets available in the PDU. If numbering of outlets used is non-contiguous: the highest outlet number is assumed as amount of measured outlets. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44568.1.1.3.1.1.7 |
| configNoNeutral Use neutral current measurements if available: 0 = No neutral current measurement, 1 = Use neutral current measurement. | column | Enumeration | .1.3.6.1.4.1.44568.1.1.3.1.1.8 |
| configNrOutletsTotal Total number of outlets available in the PDU, including hardwired outlets without a switchmeasure module. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44568.1.1.3.1.1.9 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| configDeviceIndex A unique value for each PDU. Its value
ranges between 1 and the value of pduCount. | column | Integer32 | .1.3.6.1.4.1.44568.1.1.3.1.1.1 |