saCmMtaRequireTod

SA-CM-MTA-MIB · .1.3.6.1.4.1.1429.78.1.10

Object

scalar Enumeration
This object controls if the EMTA will continue the provisioning
process if a response from a Time of Day server is not available
at provisioning step CM-8. If set to true(1) the EMTA will require
a ToD response. If set to false(0) the EMTA will request ToD but
will not require the TOD server response.
Note: For PacketCable secure provisioning, if this object is
set to false(0), and ToD is not available, MTA will probably
be unable to verify that certificates are valid and will not provision.
Note: this object can be set in the CM config file only.

Context

MIB
SA-CM-MTA-MIB
OID
.1.3.6.1.4.1.1429.78.1.10
Type
scalar
Access
readonly
Status
current
Parent
saCmMta
Siblings
9

Syntax

Enumeration

Values & Constraints

Enumerated Values
0false
1true

Related Objects

Sibling Objects