saPUFScanOnNextBoot

SA-CM-MIB · .1.3.6.1.4.1.1429.77.1.10.1.1.6

Object

column r/w Enumeration
Setting an index of this object to set(1) causes the modem to scan for
the frequency stored in saPUFFrequency.x on the next reboot and record the 
results to non-vol.
After the reboot and data is recorded, the index of this object is reset back 
to unset(0) . 
Conditions to run a scan on Next boot:
- saPUFScanOnNextBoot.x must = set (1).
- saPUFRowStatus.x must be set to active in non-vol.

Context

MIB
SA-CM-MIB
OID
.1.3.6.1.4.1.1429.77.1.10.1.1.6
Type
column
Access
readwrite
Status
current
Parent
saPUFEntry
Table
saPUFTable
Siblings
8

Syntax

Enumeration

Values & Constraints

Enumerated Values
0unset
1set

Related Objects

Sibling Objects