s5ChasType
S5-CHASSIS-MIB ·
.1.3.6.1.4.1.45.1.6.3.1.1
Object
scalar
ObjectIdentifier
The chassis type. This is 'what kind of box' is being managed. The values are defined under s5ChasTypeVal in the Registration MIB.
Context
- MIB
- S5-CHASSIS-MIB
- OID
.1.3.6.1.4.1.45.1.6.3.1.1- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- s5ChasGen
- Siblings
- 11
Syntax
ObjectIdentifier
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| s5ChasGblAttLstChng The value of sysUpTime when the last
attachment change on any board in the chassis
was detected. If none have been detected
since cold/warm start of the agent, then the
value is z… | scalar | SNMPv2-SMITimeTicks | .1.3.6.1.4.1.45.1.6.3.1.10 |
| s5ChasGblConfChngs The total number of configuration changes
(other than attachment changes, or physical
additions or removals) across all boards in
the chassis that have been detected since
cold/wa… | scalar | SNMPv2-SMICounter32 | .1.3.6.1.4.1.45.1.6.3.1.11 |
| s5ChasGblConfLstChng The value of sysUpTime when the last
configuration change (other than attachment
changes, or physical additions or removals)
on any board in the chassis was detected.
If none have… | scalar | SNMPv2-SMITimeTicks | .1.3.6.1.4.1.45.1.6.3.1.12 |
| s5ChasDescr A description of the chassis.
The value is a zero length string
if no information is available. | scalar | OctetString | .1.3.6.1.4.1.45.1.6.3.1.2 |
| s5ChasLocation The physical location of the chassis
(e.g., 'fourth floor wiring closet in
building A'). The value is a zero
length string if no information
is available. Note: this object is
di… | scalar | OctetString | .1.3.6.1.4.1.45.1.6.3.1.3 |
| s5ChasContact The textual identification of the
contact person for the chassis, together
with information on how to contact
this person. The value is a zero length
string if no information is a… | scalar | OctetString | .1.3.6.1.4.1.45.1.6.3.1.4 |
| s5ChasVer The version of the chassis in the form
'major.minor.maintenance[letters]'. If the
version is unknown or not available then
the value should be a zero length string. | scalar | OctetString | .1.3.6.1.4.1.45.1.6.3.1.5 |
| s5ChasSerNum The serial number of the chassis. If the
serial number is unknown or unavailable then
the value should be a zero length string. | scalar | OctetString | .1.3.6.1.4.1.45.1.6.3.1.6 |
| s5ChasGblPhysChngs The total number of physical changes (i.e.,
an addition or removal of a component or
sub-component) that have been detected in the
chassis since cold/warm start of the agent. | scalar | SNMPv2-SMICounter32 | .1.3.6.1.4.1.45.1.6.3.1.7 |
| s5ChasGblPhysLstChng The value of sysUpTime when the last
physical change (i.e., addition or
removal of a module or sub-module) was
detected in the chassis. If none have
been detected since cold/warm … | scalar | SNMPv2-SMITimeTicks | .1.3.6.1.4.1.45.1.6.3.1.8 |
| s5ChasGblAttChngs The total number of attachment changes
across all boards in the chassis that have
been detected since cold/warm start of
the agent. | scalar | SNMPv2-SMICounter32 | .1.3.6.1.4.1.45.1.6.3.1.9 |