rcPoeCapacity
RUGGEDCOM-POE-MIB ·
.1.3.6.1.4.1.15004.4.7.1.1
Object
scalar
r/w
W Integer32
The maximum total output power that can be provided by PoE
ports.
If the value of this object is set to '0', that means that
capacity is 'unlimited'.
When total power consumption reaches this limit, low priority PoE
ports will be shutdown.
Context
- MIB
- RUGGEDCOM-POE-MIB
- OID
.1.3.6.1.4.1.15004.4.7.1.1- Type
- scalar
- Access
- readwrite
- Status
- current
- Units
- W
- Parent
- rcPoeBase
- Siblings
- 6
Syntax
W Integer32
Values & Constraints
Object Constraints
range: 0-65535
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| rcPoeMinimumVoltage The minimum required voltage to be provided by PoE ports.
The minimum required voltage for PoE ports.
When PoE voltage droppes below this threshold, low priority PoE po… | scalar | V Integer32 | .1.3.6.1.4.1.15004.4.7.1.2 |
| rcPoeReenableTime The time to wait to turn on low priority PoE ports again after
they were shutdown due to overload condition. | scalar | seconds Unsigned32 | .1.3.6.1.4.1.15004.4.7.1.3 |
| rcPoeConsumption Current total power consumption by all PoE devices. | scalar | seconds SNMPv2-SMIInteger32 | .1.3.6.1.4.1.15004.4.7.1.4 |
| rcPoeOverheatStatus The value of this object will be set to 'true(1) if PoE is overheated.
Whenever the value of this object changes from false(2) to true(1),
the device will generate rcPo… | scalar | SNMPv2-TCTruthValue | .1.3.6.1.4.1.15004.4.7.1.5 |
| rcPoeOverloadStatus The value of this object will be set to 'true(1) if PoE is overloaded.
Whenever the value of this object changes from false(2) to true(1),
the device will generate rcPo… | scalar | SNMPv2-TCTruthValue | .1.3.6.1.4.1.15004.4.7.1.6 |
| rcPoeUndervoltageStatus The value of this object will be set to 'true(1) if PoE is undervoltage.
Whenever the value of this object changes from false(2) to true(1),
the device will generate rc… | scalar | SNMPv2-TCTruthValue | .1.3.6.1.4.1.15004.4.7.1.7 |