dot5TimerActiveMon
RFC1231-MIB ·
.1.3.6.1.2.1.10.9.5.1.7
Object
column
mandatory
Integer32
The time-out value used by the active
monitor to stimulate the enqueuing of an
AMP PDU for transmission, in units of
100 micro-seconds.
Implementors are encouraged to provide
read-write access to this object if that is
possible/useful in their system, but giving
due consideration to the dangers of
write-able timers.
Context
- MIB
- RFC1231-MIB
- OID
.1.3.6.1.2.1.10.9.5.1.7- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- dot5TimerEntry
- Table
- dot5TimerTable
- Siblings
- 10
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| dot5TimerIfIndex mandatory The value of this object identifies the
802.5 interface for which this entry
contains timer values. The value of
this object for a particular interface
… | column | Integer32 | .1.3.6.1.2.1.10.9.5.1.1 |
| dot5TimerBeaconTransmit mandatory The time-out value which determines how
long a station shall remain in the state
of transmitting Beacon … | column | Integer32 | .1.3.6.1.2.1.10.9.5.1.10 |
| dot5TimerBeaconReceive mandatory The time-out value which determines how
long a station shall receive Beacon
frames from its downstream neighbor
before entering the Bypass state, in
units of 100 micro-seconds.
… | column | Integer32 | .1.3.6.1.2.1.10.9.5.1.11 |
| dot5TimerReturnRepeat mandatory The time-out value used to ensure the
interface will return to Repeat State, in
units of 100 micro-seconds. The value
should be greater than the maximum ring
latency.
Impleme… | column | Integer32 | .1.3.6.1.2.1.10.9.5.1.2 |
| dot5TimerHolding mandatory Maximum period of time a station is
permitted to transmit frames after capturing
a token, in units of 100 micro-seconds.
Implementors are encouraged to provide
read-write acce… | column | Integer32 | .1.3.6.1.2.1.10.9.5.1.3 |
| dot5TimerQueuePDU mandatory The time-out value for enqueuing of an SMP
PDU after reception of an AMP or SMP
frame in which the A and C bits were
equal to 0, in units of 100
micro-seconds.
Implementors ar… | column | Integer32 | .1.3.6.1.2.1.10.9.5.1.4 |
| dot5TimerValidTransmit mandatory The time-out value used by the active
monitor to detect the absence of valid
transmissions, in units of 100
micro-seconds.
Implementors are encouraged to provide
read-write ac… | column | Integer32 | .1.3.6.1.2.1.10.9.5.1.5 |
| dot5TimerNoToken mandatory The time-out value used to recover from
various-related error situations [9].
If N is the maximum number of stations on
the ring, the value of this timer is
normally:
dot5TimerRet… | column | Integer32 | .1.3.6.1.2.1.10.9.5.1.6 |
| dot5TimerStandbyMon mandatory The time-out value used by the stand-by
monitors to ensure that there is an active
monitor on the ring and to detect a
continuous stream of tokens, in units of
100 micro-seconds.
… | column | Integer32 | .1.3.6.1.2.1.10.9.5.1.8 |
| dot5TimerErrorReport mandatory The time-out value which determines how
often a station shall send a Report Error
MAC frame to report its error counters,
in units of 100 micro-seconds.