rdnEvtRdbMemPoolAllocFailure
RDN-EVT-NOTIFICATIONS ·
.1.3.6.1.4.1.4981.0.2473920185
Object
notification
Not Enough Memory to create storage for the runtime records. This could lead to loss of data on replications of the redundancy databases and lead to serious problems on a switchover.
Context
- MIB
- RDN-EVT-NOTIFICATIONS
- OID
.1.3.6.1.4.1.4981.0.2473920185- Type
- notification
- Status
- current
- Parent
- rdnEvtNotifications
- Siblings
- 64
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| rdnEvtMacrtrGetQIdFailure This is an internal software error.
The MACRTR task was unable to get the DOCSIS Redundancy Agent(DRA)
task main message queue id. | notification | - | .1.3.6.1.4.1.4981.0.2473918722 |
| rdnEvtMacrtrUnknownCase This is an internal software error. The MACRTR task was received
an unexpected case, which is not handled. | notification | - | .1.3.6.1.4.1.4981.0.2473918723 |
| rdnEvtMacrtrMsgQReceiveFailure This is an internal software error. The MACRTR task caught an error
when it was receiving a message. | notification | - | .1.3.6.1.4.1.4981.0.2473918724 |
| rdnEvtMacrtrRdbDefineTableFailure This is an internal software error. The MACRTR task was unable
to register a table with the Redundancy Runtime Record
Database(RDB) for CMTS Redundancy. | notification | - | .1.3.6.1.4.1.4981.0.2473918726 |
| rdnEvtMacrtrRxUnexpectedMsgType This is an internal software error. The MACRTR task received an
unexpected message type. | notification | - | .1.3.6.1.4.1.4981.0.2473918730 |
| rdnEvtMacrtrRegTaskMonFailure This is an internal software error. The MACRTR task was unable to
register with the task monitor. | notification | - | .1.3.6.1.4.1.4981.0.2473918731 |
| rdnEvtMacrtrInvalidFuncParam This is an internal software error. The MACRTR task detected an
invalid function parameter. | notification | - | .1.3.6.1.4.1.4981.0.2473918732 |
| rdnEvtMacrtrUnknownCmId This is an internal software error. During a CMTS Switchover,
the MACRTR task was unable to determine the cable modem Id when
loading the Cable Modem runtime record. This notifica… | notification | - | .1.3.6.1.4.1.4981.0.2473918735 |
| rdnEvtBpiLoadAuthRunRecFailure This is an internal software error. The Baseline Privacy
Interface(BPI) task was unable to load the Authorization Key
runtime record during a CMTS Switchover. | notification | - | .1.3.6.1.4.1.4981.0.2473919513 |
| rdnEvtBpiLoadTekRunRecFailure This is an internal software error. The Baseline Privacy
Interface(BPI) task was unable to load the TEK runtime
record during a CMTS Switchover. | notification | - | .1.3.6.1.4.1.4981.0.2473919514 |
| rdnEvtBpiLoadCmCertificateFailure This is an internal software error. The Baseline Privacy
Interface(BPI) task was unable to load the Cable Modem
Certificate during a CMTS Switchover. | notification | - | .1.3.6.1.4.1.4981.0.2473919525 |
| rdnEvtDraTaskSpawnFailure This is an internal software error. Unable to create the
DOCSIS Redundancy Agent(DRA) task. This notification is only
generated on the BSR 64000. | notification | - | .1.3.6.1.4.1.4981.0.2473919745 |
| rdnEvtDraMsgQCreateFailure This is an internal software error. Unable to create the DRA task's
message queue. This notification is only generated on the BSR 64000. | notification | - | .1.3.6.1.4.1.4981.0.2473919746 |
| rdnEvtDraMsgQReceiveFailure This is an internal software error. DRA task's caught an error
when it was receiving a message. This notification is only
generated on the BSR 64000. | notification | - | .1.3.6.1.4.1.4981.0.2473919747 |
| rdnEvtDraRegTaskMonFailure This is an internal software error. DRA task was unable to register
with the task monitor. This notification is only
generated on the BSR 64000. | notification | - | .1.3.6.1.4.1.4981.0.2473919748 |
| rdnEvtDraCreateRdbFailure This is an internal software error. DRA task was
unable to create a Redundancy Runtime Database for CMTS Redundancy.
This notification is only generated on the BSR 64000. | notification | - | .1.3.6.1.4.1.4981.0.2473919749 |
| rdnEvtDraRxUnexpectedMsgType This is an internal software error. DRA task received an unexpected
message type. This notification is only generated on the BSR 64000. | notification | - | .1.3.6.1.4.1.4981.0.2473919754 |
| rdnEvtDraRxUnexpectedMsgSubType This is an internal software error. DRA task received an unexpected
message sub-type. This notification is only generated on the
BSR 64000. | notification | - | .1.3.6.1.4.1.4981.0.2473919755 |
| rdnEvtDraTmrInitFailure This is an internal software error. DRA was unable to
create its timers. This notification is only generated
on the BSR 64000. | notification | - | .1.3.6.1.4.1.4981.0.2473919761 |
| rdnEvtDraInvalidFuncParam This is an internal software error. The DRA task detected an
invalid function parameter. This notification is only generated
on the BSR 64000. | notification | - | .1.3.6.1.4.1.4981.0.2473919767 |
| rdnEvtDraInvalidMsgParam This is an internal software error. The DRA task detected an
invalid message parameter. This notification is only generated
on the BSR 64000. | notification | - | .1.3.6.1.4.1.4981.0.2473919768 |
| rdnEvtRdbMsgQCheckFailure This is an internal resource error. The is a major component
failure with on of RDB's message queues, that may lead to
system failures. Try correcting this problem by resetting … | notification | - | .1.3.6.1.4.1.4981.0.2473920006 |
| rdnEvtRdbCreateDatabaseFailure This is an internal error. There is a major component
failure creating a database for CMTS redundancy, this could
lead to system failures. This notification is only generated
on… | notification | - | .1.3.6.1.4.1.4981.0.2473920025 |
| rdnEvtRdbInitDatabaseFailure This is an internal error. There is a major component
failure initializing a database for CMTS redundancy, this could
lead to system failures. This notification is only generated… | notification | - | .1.3.6.1.4.1.4981.0.2473920026 |
| rdnEvtRdbSemCreateFailure This is an internal software error. RDB task was unable to create
a semaphore for mutual exclusion. This notification is only generated
on the BSR 64000. | notification | - | .1.3.6.1.4.1.4981.0.2473920048 |
| rdnEvtRdbUnknownTableFromPeer Software versions may not be the same on the Primary and
the Spare. This may cause a loss of data on replications of
the redundancy databases and lead to serious problem on a
swit… | notification | - | .1.3.6.1.4.1.4981.0.2473920145 |
| rdnEvtRdbDefineTableNotEnoughMemory Not Enough Memory to register a new table with RDB. This could
lead loss of data on replications of the redundancy databases and
lead to serious problem on a switchovers. | notification | - | .1.3.6.1.4.1.4981.0.2473920174 |
| rdnEvtRdbMsgBufAllocFailure Not Enough Memory to create message buffers in RDB. This could
lead loss of data on replications of the redundancy databases and
lead to serious problem on a switchovers. Reset t… | notification | - | .1.3.6.1.4.1.4981.0.2473920179 |
| rdnEvtRdbMallocFailure Memory allocation for internal RDB structure reported an error.
This card is most like running low on memory. Reset the card
reporting this problem. | notification | - | .1.3.6.1.4.1.4981.0.2473920186 |
| rdnEvtDrmSpareCmtsActive This is reported when a Spare CMTS becomes active
for a redundant primary CMTS in a BSR 64000 chassis. | notification | - | .1.3.6.1.4.1.4981.0.2473920312 |
| rdnEvtDrmFailedAutoTakeover This is reported when a Primary CMTS goes down, and
an auto-takeover fails to make Spare CMTS become the
active CMTS in a BSR 64000 chassis. | notification | - | .1.3.6.1.4.1.4981.0.2473920313 |
| rdnEvtDrmFailedAutoGiveback This is reported when a active Spare CMTS goes down, and
an auto-giveback fails to make Primary CMTS become the
active CMTS in a BSR 64000 chassis. | notification | - | .1.3.6.1.4.1.4981.0.2473920314 |
| rdnEvtDrmSpareXmittersRcvrsMismatch This is reported when Spare CMTS has fewer transmitters or
receivers than a Primary CMTS. The Spare CMTS must have at
least as many transmitters and receivers as each Primary CMT… | notification | - | .1.3.6.1.4.1.4981.0.2473920315 |
| rdnEvtDrmSpareDtxActive This is reported when a Spare DTX becomes active
for a redundant primary DTX in a BSR 64000 chassis. | notification | - | .1.3.6.1.4.1.4981.0.2473920431 |
| rdnEvtDrmFailedDtxAutoTakeover This is reported when a Primary DTX goes down, and
an auto-takeover fails to make Spare DTX become the
active DTX in a BSR 64000 chassis. | notification | - | .1.3.6.1.4.1.4981.0.2473920432 |
| rdnEvtDrmFailedDtxAutoGiveback This is reported when a active Spare DTX goes down, and
an auto-giveback fails to make Primary DTX become the
active DTX in a BSR 64000 chassis. | notification | - | .1.3.6.1.4.1.4981.0.2473920433 |
| rdnEvtDrmSpareDrxActive This is reported when a Spare DRX becomes active
for a redundant primary DRX in a BSR 64000 chassis. | notification | - | .1.3.6.1.4.1.4981.0.2473920441 |
| rdnEvtDrmFailedDrxAutoTakeover This is reported when a Primary DRX goes down, and
an auto-takeover fails to make Spare DRX become the
active DRX in a BSR 64000 chassis. | notification | - | .1.3.6.1.4.1.4981.0.2473920442 |
| rdnEvtDrmFailedDrxAutoGiveback This is reported when a active Spare DRX goes down, and
an auto-giveback fails to make Primary DRX become the
active DRX in a BSR 64000 chassis. | notification | - | .1.3.6.1.4.1.4981.0.2473920443 |
| rdnEvtAccrtrRdbDefineTableFailure This is an internal software error. The Accrtr task was unable
to register a table with the Redundancy Runtime Record
Database(RDB) for CMTS Redundancy. | notification | - | .1.3.6.1.4.1.4981.0.2473920769 |
| rdnEvtAccrtrRdbNextFailure This is an internal software error. The Accrtr task was unable
retrieve the next runtime record from Redundancy Runtime Record
Database(RDB) for CMTS Redundancy. | notification | - | .1.3.6.1.4.1.4981.0.2473920775 |
| rdnEvtAccrtrNotFrozenLoad This is an internal software error. The Accrtr task was not frozen
when trying to load the runtime records for a particular cable
modem during a CMTS Switchover. | notification | - | .1.3.6.1.4.1.4981.0.2473920781 |
| rdnEvtArdrtrRdbDefineTableFailure This is an internal software error. The Address Resolution
Database Run Time Records(Ardrtr) task was unable
to register a table with the Redundancy Runtime Record
Database(RDB)… | notification | - | .1.3.6.1.4.1.4981.0.2473921025 |
| rdnEvtArdrtrRdbNextFailure This is an internal software error. The Address Resolution
Database Run Time Records(Ardrtr) task was unable
retrieve the next runtime record from Redundancy Runtime Record
Data… | notification | - | .1.3.6.1.4.1.4981.0.2473921031 |
| rdnEvtArdrtrNotFrozenLoad This is an internal software error. The Address Resolution
Database Run Time Records(Ardrtr) task was not frozen
when trying to load the runtime records for a particular cable
mo… | notification | - | .1.3.6.1.4.1.4981.0.2473921035 |
| rdnEvtArdrtrLoadFailure This is an internal software error. The Address Resolution
Database Run Time Records(Ardrtr) task was unable to load
the runtime records do to an invalid cable modem Id during a … | notification | - | .1.3.6.1.4.1.4981.0.2473921039 |
| rdnEvtMacmgrValidateCmError This is an internal software error. The Macmgr task received
a 'Validate Cable Modem' message from BPI, which contained an
invalid cable modem index. | notification | - | .1.3.6.1.4.1.4981.0.2473921541 |
| rdnEvtMacmgrInvalidateCmError This is an internal software error. The Macmgr task received
a 'Invalidate Cable Modem' message from BPI, which contained an
invalid cable modem index. | notification | - | .1.3.6.1.4.1.4981.0.2473921568 |
| rdnEvtMacmgrNullPtr This is an internal software error. The Macmgr task called a
function with a null pointer. | notification | - | .1.3.6.1.4.1.4981.0.2473921577 |
| rdnEvtDocsifCmtsCmIndexAddFreeListFailure This is an internal software error. Unable to add
the docsIfCmtsCmStatusIndex to a list of indexes available to use. | notification | - | .1.3.6.1.4.1.4981.0.2473924360 |
| rdnEvtDocsifCmtsCmIndexDelFreeListFailure This is an internal software error. Unable to remove
the docsIfCmtsCmStatusIndex from a list of indexes available to use. | notification | - | .1.3.6.1.4.1.4981.0.2473924362 |
| rdnEvtDocsifCmtsCmIndexReloadFreeListFailure This is an internal software error. Unable to reload
the docsIfCmtsCmStatusIndex from a list of indexes available to use. | notification | - | .1.3.6.1.4.1.4981.0.2473924371 |
| rdnEvtUpcTaskSpawnFailure This is an internal software error. Unable to create the
Up Converter(UPC) task. | notification | - | .1.3.6.1.4.1.4981.0.2473925121 |
| rdnEvtUpcMsgQCreateFailure This is an internal software error. Unable to create the UPC task's
message queue. | notification | - | .1.3.6.1.4.1.4981.0.2473925122 |
| rdnEvtUpcMsgQReceiveFailure This is an internal software error. UPC task's caught an error
when it was receiving a message. | notification | - | .1.3.6.1.4.1.4981.0.2473925123 |
| rdnEvtUpcRegTaskMonFailure This is an internal software error. UPC task was unable to register
with the task monitor. | notification | - | .1.3.6.1.4.1.4981.0.2473925124 |
| rdnEvtUpcRxUnexpectedMsgType This is an internal software error. UPC task received an unexpected
message type. | notification | - | .1.3.6.1.4.1.4981.0.2473925126 |
| rdnEvtUpcRxUnexpectedMsgSubType This is an internal software error. UPC task received an unexpected
message sub-type. | notification | - | .1.3.6.1.4.1.4981.0.2473925127 |
| rdnEvtUpcSemCreateFailure This is an internal software error. UPC task was unable to create a
semaphore for mutual exclusion. | notification | - | .1.3.6.1.4.1.4981.0.2473925142 |
| rdnEvtSvcfloNullPtr This is an internal software error. The SVCFLO task called a
function will a null pointer. | notification | - | .1.3.6.1.4.1.4981.0.2473925891 |
| rdnEvtSvcfloWriteNextFlowTlvError This is an internal software error. The SVCFLO task
detected an error when trying to backup a Service Flow TLV for
CMTS Redundancy. This TLV is not replicated to the peer CMTS,
an… | notification | - | .1.3.6.1.4.1.4981.0.2473925895 |
| rdnEvtSvcfloSidInsertFailure This is an internal software error. The SVCFLO task
was unable to store the cable modems Service Id (SID). | notification | - | .1.3.6.1.4.1.4981.0.2473925899 |
| rdnEvtUbshaCollectionRspMallocError This is an internal software error. Failed to allocate memory during
upstream channel sampling response. | notification | - | .1.3.6.1.4.1.4981.0.2473927699 |
| rdnEvtUbshaTaskSuspended This is an internal software error. The Upstream Bandwidth
Scheduler(UBS) task suspended itself. Reset CMTS to clear the
error. | notification | - | .1.3.6.1.4.1.4981.0.2473927709 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| DOCS-CABLE-DEVICE-MIBdocsDevEvLevel The priority level of this event, as defined by the
vendor. These are ordered from most serious (emergency)
to least serious (debug).
emergency(1) events indicate … | column | Enumeration | .1.3.6.1.2.1.69.1.5.8.1.5 |
| DOCS-CABLE-DEVICE-MIBdocsDevEvId For this product, uniquely identifies the type of event
that is reported by this entry. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.2.1.69.1.5.8.1.6 |
| DOCS-CABLE-DEVICE-MIBdocsDevEvText Provides a human-readable description of the event,
including all relevant context (interface numbers,
etc.). | column | SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.2.1.69.1.5.8.1.7 |
| DOCS-IF-MIBdocsIfDocsisBaseCapability Indication of the DOCSIS capability of the device. | scalar | DocsisVersion | .1.3.6.1.2.1.10.127.1.1.5 |
| IF-MIBifPhysAddress The interface's address at its protocol sub-layer. For
example, for an 802.x interface, this object normally
contains a MAC address. The interface's media-specific MIB
must defi… | column | SNMPv2-TCPhysAddress | .1.3.6.1.2.1.2.2.1.6 |