flapMissThreshold

RDN-CABLE-SPECTRUM-MIB · .1.3.6.1.4.1.4981.6.1.1.1.1.6

Object

column r/w modem Integer32
Specifies the maximum threshold for the number of consecutive miss
counts during a polling cycle.  If the flap miss counts goes over 
this threshold, the modem will be added into the flap list. 
              
Polling is maintained between the CMTS and the cable modem  
every 10 seconds.  The flapMissThreshold specifies the maximum 
number of consecutive missed counts during one station maintenance
poll interval.  If there are more than 16 consecutive miss counts 
during one polling cycle, the modem will de-insert and attempt to 
range again.
                                  
The value ranges from 1 to 12 consecutive counts. 
The default value is 6.

Context

MIB
RDN-CABLE-SPECTRUM-MIB
OID
.1.3.6.1.4.1.4981.6.1.1.1.1.6
Type
column
Access
readwrite
Status
current
Units
modem
Parent
rdnFlapCmCmtsStatusEntry
Table
rdnFlapCmCmtsStatusTable
Siblings
8

Syntax

modem Integer32

Values & Constraints

Object Constraints
range: 1-12

Related Objects

Sibling Objects