rc2kChassisPortLed2Status
RC-2K-MIB ·
.1.3.6.1.4.1.2272.1.100.1.12
Object
scalar
OctetString
This is applicable only for VSP8200, VSP8400 & VSP8600.
Each octet string contains the value of a port LED status. One octet
is used for each port. Each octet contains two nibbles (two 4 bits).
From left to right, the first nibble (higher order 4 bits) of the
octet represents the Link/Activity LED (The left one of the two for
fiber port. Each copper port has only one LED). The second nibble
(lower order 4 bits) of the octet represents the Speed/InUse LED (The
right one of the two for fiber port). And use the ifIndex as the position
starting from 192th octet. Such 192th octet for 1/1, 193 for 1/2, so on
so forth.
The following shows the meaning for each nibbles:
first 4 bits value meaning for activity
--------------------------------------------------------------------------------------------------------
0 : port not valid or not present
1 Light Off : admin enabled & no link & no fault
on all channels
2 Slow Blinking Green : admin disable
or one or more channelized ports admin disable
3 Blinking Amber : remote fault on 10G/40G fiber port
4 Solid Amber : local fault on one or more
channels on 10G/40G fiber port
5 Solid Green : link up & no activity on one or more
channels on 10G/40G fiber port
: link up with 100M speed on 10G copper port
6 Solid Amber : link up with 1G speed on 10G copper port
7 Solid Blue : link up with 10G speed on 10G copper port
8 Random Blinking Green : link up & activity on one or more
channels on 10G/40G fiber port
: activity with 100M speed on 10G copper port
9 Random Blinking Amber : activity with 1G speed on 10G copper port
10 Random Blinking Blue : activity with 10G speed on 10G copper port
second 4 bits value meaning for Speed.
------------------------------------------------------------------------------------------------------
0 : port not valid or not present
1 Blinking Green : 1G speed on 10G fiber port(SFP+)
2 Solid Green : 10G speed on 10G fiber port
: channelized on on 40G fiber port
: 1G speed on 1G port
3 Light Off : channelized off on 40G fiber port
: 10M speed on 1G port
4 Solid Amber : 100M speed on 1G port
5 Blinking Amber : Copper port link up with 100Mbps speed with PoE
6 Blinking Blue : Copper port link up with 10Gbps speed with PoE
7 Solid Blue : Copper port link up with 10Gbps speed
8 Blinking Amber Green : Copper port link up with 2.5Gbps speed with PoE
9 Solid Amber Green : Copper port link up with 2.5Gbps speed
10 Blinking Amber Blue : Copper port link up with 5Gbps speed with PoE
11 Solid Amber Blue : Copper port link up with 5Gbps speed
Context
- MIB
- RC-2K-MIB
- OID
.1.3.6.1.4.1.2272.1.100.1.12- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- rc2kChassis
- Siblings
- 13
Syntax
OctetString
Values & Constraints
Object Constraints
range: 1024-1024
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| rc2kChassisPortOperStatus A bit array that contains the oper-status
of the ports in the device. 2 bits are used
for each port. The high order 2 bits of the
first octet represent port #0, the next two
bit… | scalar | OctetString | .1.3.6.1.4.1.2272.1.100.1.1 |
| rc2kChassisSystemTempLedColor Used to indicate the led color of the system temperature
which is under or above the threshold. The threshold is 60 degree
in celsius.
'green' means normal. And temperature under… | scalar | Enumeration | .1.3.6.1.4.1.2272.1.100.1.10 |
| rc2kChassisPortLedStatus This is applicable only for VSP4K. Max port 3/64
A bit array that contains the LED status
of the ports in the device. 1 octet is used
for each port. Starting at postion as ifInde… | scalar | OctetString | .1.3.6.1.4.1.2272.1.100.1.11 |
| rc2kChassisPortLicenseStatus This is applicable only for VSP7K. The string is 56 octets long,
for a total of 448 bits. Each bit corresponds to a port, as represented
by its ifIndex value. When a bit is set (v… | scalar | OctetString | .1.3.6.1.4.1.2272.1.100.1.13 |
| rc2kChassisPortLed3Status This is applicable only for Tomahawk 100G port, DSG9032, DSG8064,
T3x032(with 32 100G ports), T3x048v(with 48 25G ports plus 8 100G ports)
and VSP4900.
For DSG9032, each 100G por… | scalar | OctetString | .1.3.6.1.4.1.2272.1.100.1.14 |
| rc2kChassisTemperature Used to indicate the core operating temperature
of the chassis. This value represents the degree
in celsius of the air inside the chassis. | scalar | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.2272.1.100.1.2 |
| rc2kChassisAmbientLowerTemperature obsolete Used to indicate the temperature of the air
entering the fan at the lower half of the chassis. | scalar | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.2272.1.100.1.3 |
| rc2kChassisAmbientUpperTemperature obsolete Used to indicate the temperature of the air
entering the fan at the upper half of the chassis. | scalar | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.2272.1.100.1.4 |
| rc2kChassisBaseMacAddr base mac addr | scalar | SNMPv2-TCMacAddress | .1.3.6.1.4.1.2272.1.100.1.5 |
| rc2kChassisMacAddrCapacity Mac Address Capacity | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2272.1.100.1.6 |
| rc2kChassisPbtMacAddr pbt mac addr | scalar | SNMPv2-TCMacAddress | .1.3.6.1.4.1.2272.1.100.1.7 |
| rc2kChassisUserLabel1 user defined management information. This can be used to
provide extra information about the chassis. Syntax can be
as expected by the management system | scalar | OctetString | .1.3.6.1.4.1.2272.1.100.1.8 |
| rc2kChassisPbtMacAddrList List of 8 Pbt Mac addresses. The first Pbt Mac Address
is rc2kChassisPbtMacAddr. The other 7 Pbt Mac Addresses
are derived by increment 1 to the previous mac sequencially
start fr… | scalar | OctetString | .1.3.6.1.4.1.2272.1.100.1.9 |